MRV Communications, Inc. – Insta llation Manual
27
Table 6: DIP Switch Setting for TereScope
TS700/155 TS800/155
Function OFF ON OFF ON
Fast Ethernet 4,5 – 1,2,3,4
ATM/OC3/STM1: 155 Mbps 4,5 2,3,4 1
SMPTE 143 Mbps – 3,4
1,2
E3:34.368 Mbps 5 4
1,2,4 3
T3:44.736 4 5
2,4 1,3
OC1/STMO:51.840 Mbps 1,4 2,3
Customized 1 4 1,2,3
Customized 2 1,3,4 2
Open Protocol 1,2,3 4
Mode Select DIP switch toggle
Set DIP switch toggles 1 and 2 to the OFF position for normal operation. (In
TS800/155 and TS800/155-F set the DS2 1, 2, 3 and 4 toggles to OFF position)
2 – TS700/100 (Fast ethernet)
Compatibility
Peripheral equipment
Check the operation of the peripheral equipment connected with cables (see
Configuration 1 below).
Interfaces
Check the specifications compatibility (type, data rate) between the TereScope and
the peripheral equipment interfaces.
Test equipment
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link
quality. A portable one is preferable since it is more convenient for use in the field.
A ping test or a file transfer between two workstations - connected to the
networking equipment - is useful and easy to implement for testing the
performance of the whole configuration.
Setup
DIP Switch
Set DIP switch toggles 1 and 2 to the OFF position for normal operation.
Set DIP switch toggle 4 for the speed. Usually with Cisco Switches set the TS to
Auto-negociation mode.