MRV Communications TS800/155, TS700/155, TS700/100, TS700/G user manual Optimal Mounting

Models: TS800/155 TS700/100 TS700/155 TS700/G

1 77
Download 77 pages 1.79 Kb
Page 29
Image 29

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

Figure 2.1: Optimal Mounting

TereScope at edge of roof so that heat rising from roof surface does not affect beam

Beam path more than 4.5 m (15 ft) above surface to avoid traffic and rising heat.

Figure 2.2: Acceptable Mounting

Figure 2.3 shows an unrecommended TereScope link location because of interference by IR. Notice that the TereScopes are mounted far from the rooftop edges or are too close to the ground.

TereScope not at edge of roof.

Less than 4.5 m (15 ft) between beam path and heat-emitting surface.

TereScope not at edge of roof.

Beam path passes too close to ground. Heat rising causes scintillation. Allow 4.5 m (15 ft) between ground and beam path.

Figure 2.3: Unrecommended Mounting

19

Page 29
Image 29
MRV Communications TS800/155, TS700/155, TS700/100, TS700/G user manual Optimal Mounting