MRV Communications TS700/100, TS700/155, TS800/155, TS700/G user manual Bench test, IR link

Models: TS800/155 TS700/100 TS700/155 TS700/G

1 77
Download 77 pages 1.79 Kb
Page 38
Image 38

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

3–TS700/G

Compatibility

Peripheral equipment

Check the operation of the peripheral equipment connected with cables (see Configuration 1 below).

Interfaces

Check the specifications compatibility (type, data rate) between the TereScope and the peripheral equipment interfaces.

Test equipment

Chose an appropriate Bit Error Rate (BER) tester for checking the physical link quality. A portable one is preferable since it is more convenient for use in the field.

A ping test or a file transfer between two workstations - connected to the networking equipment - is useful and easy to implement for testing the performance of the whole configuration.

Setup

DIP Switch

Set DIP switch 1 to OFF (attenuated transmitter) in order to enable short range operation with minimal extra attenuation. Set DIP switch 4 to appropriate protocol – ON for Gigabit Ethernet, OFF for FiberChannel.

Bench test

To learn more about TereScope Bench Test, please refer to Appendix E.

Peripheral equipment and cable testing

Peripheral/Testing

Equipment

Configuration 1: (Applicable to all models)

Peripheral/Testing

Equipment

RX TX

RX TX

Cables

1-way Airlink BER test

Configuration 2: (Applicable to all models)

BER Tester

TX RX

 

 

IR link

 

TX

TS

TS

TX

 

 

RX

UWIN

UWIN

RX

 

 

28

Page 38
Image 38
MRV Communications TS700/100, TS700/155, TS800/155, TS700/G user manual Bench test, IR link