M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l
TS700/G (Giga-Light)
Part Number Model
Application / Data Protocol
Performance
Transmitter
Receiver
Interface
Power Supply
Environmental Information
Mechanical Design
Diagnostics
Indicators /
Selectors
Rate
Range (1) @ 3dB/km @ 5dB/km @ 10dB/km @ 17dB/km @ 30dB/km
Minimum Range
Bit Error Rate
MTBF
Light source
Wavelength
Total Output power
Beam divergence
Detector
Field of view
Sensitivity
Type
Connectors
Wavelength
Cable
Output power
Receiver operating range
Operating Temp.
Storage Temp.
Humidity
Housing
Eye safety Class
Dimensions [mm]
Weight | Unit |
| Accessories |
|
|
| Indicators |
|
|
| Selectors |
|
|
| Diagnostic |
|
|
|
|
| Management |
TS1000/A/YUW/VS
TS700/G
1.0625Gbps & 1.25 Gbps
1000 m
900m
690m
540m
400m 40 m
Less than
10years
1VCSEL
15 mW
3.5 mrad
APD
8mrad
Fiber Optic Transceiver - Multimode (Singlemode available upon request)
SC (other connectors available)
850 nm (other wavelength available)
Up to 220m length @ 62.5um
&
Up to 500m length @ 50um
0 to
Factory set:
or
95%
Weatherproof – IP 66
1M
470 X 282 X 390
5kg 3.5 kg
Airlink: Flag, Fiber Optic: Flag, Laser enabled.
Receive Signal Strength (Digital Display)
Data Rate, Power attenuator (for short distance), IP address setting
4 dry contacts for: Airlink Flag, Fiber Optic Flag, Laser enabled and Power
SNMP Protocol –
Notes: | (1) 3dB/Km: Light rain (5 - 10mm/hr) - Light Haze |
| 5dB/Km: Light to medium rain (15 - 20mm/hr) - Haze |
| 10dB/Km: Medium to Heavy rain |
| 17dB/Km: Cloudburst |
| 30dB/Km: Rain (up to |
50