Using the BayStack 410-24T 10BASE-T Switch

Table 3-4.

System Characteristics Screen Fields

 

 

 

Field

Description

 

 

 

Operation Mode

Read-only field that indicates the operation mode of the unit, for example:

 

• When the unit is part of a stack configuration, the (read-only) field indicates the

 

unit is operational in a stack, and lists the current unit number of this switch. In

 

this example (see Figure 3-5 on page 3-15), the current unit number is Unit 2.

 

• When the unit is not part of a stack configuration (operating standalone), the

 

read-only field indicates the unit is operating as a switch. When in this operation

 

mode, the Size of Stack and Base Unit fields (see following description) do not

 

appear.

 

Size of Stack

This read-only field only appears when the switch is participating in a stack

 

configuration. This field indicates the number of units configured in the stack

 

configuration (1 to 8 units maximum).

Base Unit

This read-only field only appears when the switch is participating in a stack

 

configuration. This field indicates the unit number of the switch that is currently

 

operating as the base unit.

MAC Address

The MAC address of the BayStack 410-24T switch or, when the switch is participating

 

in a stack configuration, the MAC address of the stack configuration.

Reset Count

A read-only field that indicates the number of resets since the operational firmware

 

was first loaded on the switch.

 

Default Value

1

 

Range

0 to 232 -1

Last Reset Type

A read-only field that indicates the last type of reset.

 

Default Value

Power Cycle

 

Range

Power Cycle, Software Download, Management Reset,

 

 

Management Factory Reset

Power Status

A read-only field that indicates the current power source (primary, RPSU, or both).

 

Default Value

Primary Power

 

Range

Primary Power, Redundant Power, Primary and Redundant Power

Local MDA Type

A read-only field that indicates the MDA type that is configured in this unit.

sysDescr

A read-only field that specifies the hardware and software version.

 

 

(continued)

3-16

309985-B Rev 00

Page 154
Image 154
Nortel Networks 24T manual System Characteristics Screen Fields