Using the BayStack 410-24T 10BASE-T Switch

#Caution

#Omitting a Forward slash (/) when the entry is continued to the next

#line, can cause the interruption of the booting process or the

#incorrect image file to download. Always include forward slashes

#where needed.

#

#Important Note:

#If a leading zero (0) is used in the IP address it is calculated as an

#octal number. If the leading character is "x" (upper or lower case),

#it is calculated as a hexadecimal number. For example, if an IP address

#with a base 10 number of 45 is written as .045 in the BOOTPTAB.TXT file,

#the Bootp protocol assigns .037 to the client.

#

#Global entries are defined that specify the parameters used by every device.

#Note that hardware type (ht) is specified first in the global entry.

#

#The following global entry is defined for an Ethernet device. Note that this

#is where a client's subnet mask (sm) and default gateway (gw) are defined.

global1/

ht=ethernet/

hd=c:\opt\images/

sm=255.255.255.0/

gw=192.0.1.0

#The following sample entry describes a BootP client:

bay1ht=ethernetha=0060fd000000ip=192.0.0.1hd=c:\ezlan\imagesbf=b410_100.img

# Where:

 

#

host name:

bay1

#

hardware type:

Ethernet

#

MAC address:

00-60-FD-00-00-00

#

IP address:

192.0.0.1

#home directory of boot file: c:\ezlan\images

#

boot file:

b410_100.img

F-2

309985-B Rev 00

Page 304
Image 304