Introduction to the BayStack 410-24T Switch
In this example, port 23 becomes the designated Monitor Port for switch S1 when you press [Enter] in response to the [Yes] screen prompt.
Note: The screen data displayed at the bottom of the screen changes to show the new currently active port mirroring configuration after you press [Enter].
The Monitoring Mode field [ Address A - > Address B ] indicates that all traffic transmitted by address A to address B will be monitored by the StackProbe attached to Monitor port 23.
Note: When you enter MAC addresses in this screen, they are also displayed in the MAC Address Table screen (see “MAC Address Table” on page
Port Mirroring Configuration |
| |||
Monitoring Mode: | [ | Address A | ||
Monitor Unit/Port: | [ | /23 ] |
| |
Unit/Port X: | [ | / | ] |
|
Unit/Port Y: | [ | / | ] |
|
Address A: [
Address B: [
Is your port mirroring configuration complete? [ Yes ]
| Currently Active Port Mirroring Configuration | |||
| ||||
Monitoring Mode: | or | Port Y | Monitor Port: 23 | |
Port X: 25 | Port Y: 24 |
|
|
|
Use space bar to display choices, press <Return> or <Enter> to select choice. Press
Figure 1-53. Port Mirroring Address-Based Screen Example
|