Using the BayStack 410-24T 10BASE-T Switch

Table 3-31. Console/Comm Port Configuration Screen Fields (continued)

FieldDescription

Console Switch

Enables password protection for accessing the console interface (CI) of a

Password Type

standalone switch through a console terminal.

 

If you set this field to Required, you can use the Logout option to restrict access

 

to the CI. Thereafter, you will need to specify the correct password at the

 

console-terminal prompt. See Console Read-Only Switch Password and

 

Console Read-Write Switch Password for more information.

 

Default Value

None

 

Range

None, Local Password, RADIUS Authentication

Console Stack

Enables password protection for accessing the console interface (CI) of any

Password Type

participating switch in a stack configuration, through a console terminal.

 

If you set this field to Required, you can use the Logout option to restrict access

 

to the CI of any stack unit. Thereafter, you will need to specify the correct

 

password at the console-terminal prompt when accessing the stack. See

 

Console Read-Only Stack Password and Console Read-Write Stack Password

 

for more information.

 

Default Value

None

 

Range

None, Local Password, RADIUS Authentication

TELNET Switch

Enables password protection for accessing the console interface (CI) of a

Password Type

standalone switch through a TELNET session.

 

If you set this field to Required, you can use the Logout option to restrict access

 

to the CI. Thereafter, you will need to specify the correct password at the

 

console-terminal prompt. See Console Read-Only Switch Password and

 

Console Read-Write Switch Password for more information.

 

Default Value

None

 

Range

None, Local Password, RADIUS Authentication

 

 