5.3.2 RS-232C Interface (OKI Standard Type)
1 Interface signals
Pin No.
1
2
3
4
6
(Note 2)
7
20
5,8 to 10,11,
12 to 19, 21 to 24
25 (Note 2)
Signal
Protective ground
Transmitted Data
Received Data
Request to Send
Data Set Ready
Signal Ground
Data Terminal Ready
-
Initial
Code
PG
TD
RD
RTS
DSR
SG
DTR
-
INIT
Signal
-
From printer
To printer
From printer
To printer
-
From Printer
-
To Printer
Function
Frame ground
Data from printer
Data to printer
Indicates printer cannot receive data in printer and Customer Display Busy/Ready protocol
Indicates that data can be sent
Signal ground
Indicates printer cannot receive data in printer Busy/Ready protocol
Unused
Requests printer reset