Monitor Lamp indicators

Managing the indicated problems

If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as follow.

Attention

Power indicator (STANDBY (R) / ON (G))

Lamp1 indicator (LAMP1) Lamp2 indicator (LAMP2)

Temperature indicator (TEMP) Filter indicator (FILTER)

JJLAMP1/LAMP2 indicator

Lamp

Information

Check point

Remedial measure

indication

 

 

 

 

 

 

zzThis lamp monitor lights up when the

 

Indicates the time

zzDid you notice a “REPLACE

lamp unit used hours have reached

 

LAMP” message on the screen

2 800 hours (when [HIGH] is selected

Lighting in red

for replacing the

when turning on the projector

as the [LAMP POWER] setting).

 

lamp unit.

 

power supply?

zzRequest the dealer to replace the lamp

 

 

 

 

 

unit.

 

 

 

zzInstall the lamp unit.

Blinking in red

Lamp unit is not

zzCheck the lamp unit

zzWhen lamp unit is installed and still

(once)

installed.

compartment.

having the indicator lights, contact to

 

 

 

the dealer.

 

 

zzDid you turn the power back

zzWait until the lamp has cooled off, and

 

 

on immediately after turning it

then turn on the power.

Blinking in red

Error is detected

off?

 

zzSome error has arisen in the

 

(3 times)

in the lamp circuit.

zzTurn off the MAIN POWER switch

lamp circuit.

 

 

using the procedure on page 40 and

 

 

zzCheck for fluctuation (or drop)

 

 

consult the dealer.

 

 

in the source voltage.

 

 

 

Note

zzIf no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.

Maintenance