NETWORK menu
JJError information page
When “Error (Detail)” is displayed on the status information screen, click it to display the error details. zzDepending on the nature of the error, the projector may be placed in the standby mode for its own
protection.
Settings
OK: Normal operation
FAILED: Occurrence of trouble
When [FAILED] has appeared for an item | ||
| ||
Parameter | Description | |
MAIN CPU BUS | Trouble has occurred in the microcomputer circuitry. Consult your dealer. | |
FAN | Trouble has occurred in the fan or its drive circuit. Consult your dealer. | |
INPUT AIR TEMPERATURE | The input air temperature is too high. It may be that the projector is being used in an | |
operating environment where the temperature is high such as near a heating appliance. | ||
| ||
| The temperature inside the projector is high. It may be that the projector is being used | |
OPTICS MODULE TEMPERATURE | in an operating environment where the temperature is high such as near a heating | |
| appliance. | |
AROUND LAMP TEMPERATURE | The temperature around the lamp is too high. It may be that the projector’s ventilation | |
holes are blocked. | ||
| ||
LAMP1 REMAIN TIME | The lamp runtime has exceeded the prescribed cumulative time, and it is now time to | |
LAMP2 REMAIN TIME | replace the lamp. | |
|
| |
LAMP1 STATUS | The lamp has failed to light. | |
LAMP2 STATUS | Wait a short while for the lamp to cool off, and then turn on the power. | |
|
| |
APERTURE | Trouble has occurred in the contrast shutter circuitry. Consult your dealer. | |
INPUT AIR TEMP. SENSOR | Trouble has occurred in the sensor used to detect the input air temperature. | |
Consult your dealer. | ||
| ||
OPTICS MODULE TEMP. SENSOR | Trouble has occurred in the temperature detection sensor inside the projector. | |
Consult your dealer. | ||
| ||
AROUND LAMP TEMP. SENSOR | Trouble has occurred in the sensor used to detect the exhaust air temperature. | |
Consult your dealer. | ||
| ||
BATTERY | The backup battery has been run out. Consult your dealer. | |
AIRFLOW SENSOR | Trouble has occurred in the sensor used to detect the airflow volume. | |
Consult your dealer. | ||
| ||
COVER OPEN | The lamp unit cover is not attached securely. Check the lamp unit compartment. | |
|
| |
ACF UNIT | The air cleaning filter (ACF) is not installed or trouble has occurred. (Æ 109 page) | |
|
| |
FILTER REMAIN | The filter remaining is getting less. (Æ 108 page) | |
|
| |
BRIGHTNESS SENSOR | Trouble has occurred in the brightness sensor. If the problem cannot be corrected by | |
turning the power off and on, consult your dealer. | ||
| ||
AC POWER | AC power supply voltage input has dropped. Check that there is sufficient | |
electrical wiring capacity for the projector’s power consumption requirements. | ||
|
Note
zzThe ACCESS ERROR INFORMATLION/ACCESS INFORMATION displays the past several thousand accesses/requests. If many accesses/requests are made at a time, some of them may not be found in the information.
zzCheck the ACCESS ERROR INFORMATION/ACCESS INFORMATION regularly.
100 - ENGLISH