When “Error (Detail)” is displayed on the status information screen, click it to display the error details. zzDepending on the nature of the error, the projector may be placed in the standby mode for its own

protection.

Settings

OK: Normal operation

FAILED: Occurrence of trouble

When [FAILED] has appeared for an item

QQ

 

Parameter

Description

MAIN CPU BUS

Trouble has occurred in the microcomputer circuitry. Consult your dealer.

FAN

Trouble has occurred in the fan or its drive circuit. Consult your dealer.

INPUT AIR TEMPERATURE

The input air temperature is too high. It may be that the projector is being used in an

operating environment where the temperature is high such as near a heating appliance.

 

 

The temperature inside the projector is high. It may be that the projector is being used

OPTICS MODULE TEMPERATURE

in an operating environment where the temperature is high such as near a heating

 

appliance.

AROUND LAMP TEMPERATURE

The temperature around the lamp is too high. It may be that the projector’s ventilation

holes are blocked.

 

LAMP1 REMAIN TIME

The lamp runtime has exceeded the prescribed cumulative time, and it is now time to

LAMP2 REMAIN TIME

replace the lamp.

 

 

LAMP1 STATUS

The lamp has failed to light.

LAMP2 STATUS

Wait a short while for the lamp to cool off, and then turn on the power.

 

 

APERTURE (CONTRAST-SHUTTER)

Trouble has occurred in the contrast shutter circuitry. Consult your dealer.

INPUT AIR TEMP. SENSOR

Trouble has occurred in the sensor used to detect the input air temperature.

Consult your dealer.

 

OPTICS MODULE TEMP. SENSOR

Trouble has occurred in the temperature detection sensor inside the projector.

Consult your dealer.

 

AROUND LAMP TEMP. SENSOR

Trouble has occurred in the sensor used to detect the exhaust air temperature.

Consult your dealer.

 

BATTERY

The backup battery has been run out. Consult your dealer.

AIRFLOW SENSOR

Trouble has occurred in the sensor used to detect the airflow volume.

Consult your dealer.

 

COVER OPEN

The lamp unit cover is not attached securely. Check the lamp unit compartment.

 

 

ACF UNIT

The air cleaning filter (ACF) is not installed or trouble has occurred. (Æ 109 page)

 

 

FILTER REMAIN

The filter remaining is getting less. (Æ 108 page)

 

 

BRIGHTNESS SENSOR

Trouble has occurred in the brightness sensor. If the problem cannot be corrected by

turning the power off and on, consult your dealer.

 

AC POWER

AC power supply voltage input has dropped. Check that there is sufficient

electrical wiring capacity for the projector’s power consumption requirements.

 

Note

zzThe ACCESS ERROR INFORMATLION/ACCESS INFORMATION displays the past several thousand accesses/requests. If many accesses/requests are made at a time, some of them may not be found in the information.

zzCheck the ACCESS ERROR INFORMATION/ACCESS INFORMATION regularly.