Maintenance
Monitor Lamp indicators
JJTEMP indicator
Lamp | Information | Check point | Remedial measure | |
indication | ||||
|
|
| ||
|
| zzDid you turn on the power when | zzWait about 5 minutes in the current | |
| status. | |||
| the ambient temperature was | zzInstall the unit in a location having | ||
Lighting in red |
| lower than approx. 0 °C (32 °F)? | an ambient temperature from 0 °C | |
|
|
| (32 °F) - 45 °C (113 °F). | |
| High temperature |
| zzRemove the object that is blocking | |
| inside. (WARNING) | zzCheck the ventilation port is | the ventilation port. | |
| The filter is | zzMove the projector to a temperature | ||
Blinking in red | excessively dirty | blocked. | of 0 °C (32 °F) - 45 °C (113 °F) and | |
(once) | and the ventilation | zzIs the room air temperature too | the humidity of 20 % to 80 % (no | |
| is poor. | high? | condensation). | |
Blinking in red | High temperature | zzIs the filter indicator lighted? | zzTurn off the MAIN POWER switch | |
inside. |
| using the procedure on page 40 and | ||
(twice) | (Standby condition) |
| replace the ACF unit. | |
|
| |||
Blinking in red | Cooling fan has | — | zzTurn off the MAIN POWER switch | |
using the procedure on page 40 and | ||||
(3 times) | been stopped. | |||
| consult the dealer. | |||
|
|
|
Note
zzIf no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
JJFILTER indicator
Lamp | Information | Check point |
| Remedial measure |
indication |
| |||
|
|
|
| |
| The ACF unit has | zzCheck the [REMAINING |
|
|
Lighting in red | FILTER] of [STATUS] in | zz | Replace the ACF unit. | |
run out. | [PROJECTOR SETUP] menu. | |||
|
|
|
| |
|
| (Æpage 83) |
|
|
Blinking in red | The ACF unit is not | zzCheck the ACF unit | zz | Replace the ACF unit. |
installed. | compartment. | |||
|
|
|
| |
|
|
|
|
|
| The ACF unit |
|
|
|
| remains few. The | zzCheck the [REMAINING |
|
|
Lighting in | remaining use time | FILTER] of [STATUS] in | zzRequest the dealer to purchase the | |
orange | of the ACF unit is | [PROJECTOR SETUP] menu. |
| new ACF unit. |
| approximately 200 | (Æpage 83) |
|
|
| hours. |
|
|
|
Blinking in | The ACF unit cannot | zzIs foreign object blocking the | zzRemove the foreign object from the | |
| ACF unit. | |||
orange | operate properly. | ACF unit operation? | zzWhen the foreign object still | |
|
|
|
| remained, contact the dealer. |
Note
zzIf no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
zzWhen the ACF unit is not installed, the filter indicator will blink in red and the power will turn off in 10 minutes. zzWhen the FILTER indicator is flashing green, the Auto Cleaning Filter (ACF) is normally rolling up. zzWhen the ACF unit is operating, operational sound may be heard.
zzThe usable time after lighting of the orange lamp may be shortened in a dusty environment. The time of about 200 hours is for reference only. Contact the dealer to purchase the new ACF unit earlier.
zzIf the projector is used at elevations higher than 1 400 m above sea level with the [HIGH ALTITUDE MODE] at [OFF], the lamp life or life of other components will be shortened.
zzBefore the FILTER indicator blinks in orange when operational malfunction, mechanical sound of the clutch may be heard. zzIf the Smoke Cut Filter is installed, the green lamp, which takes longer to turn ON/OFF, will flash.
zzIf the filter is running low, only one lamp lights even if [DUAL] is selected. The lamps will light as normal once the filter has been replaced and the residual filter has been reset.