Maintenance

Monitor Lamp indicators

JJTEMP indicator

Lamp

Information

Check point

Remedial measure

indication

 

 

 

 

 

zzDid you turn on the power when

zzWait about 5 minutes in the current

 

Warm-up status

status.

 

the ambient temperature was

zzInstall the unit in a location having

Lighting in red

 

lower than approx. 0 °C (32 °F)?

an ambient temperature from 0 °C

 

 

 

(32 °F) - 45 °C (113 °F).

 

High temperature

 

zzRemove the object that is blocking

 

inside. (WARNING)

zzCheck the ventilation port is

the ventilation port.

 

The filter is

zzMove the projector to a temperature

Blinking in red

excessively dirty

blocked.

of 0 °C (32 °F) - 45 °C (113 °F) and

(once)

and the ventilation

zzIs the room air temperature too

the humidity of 20 % to 80 % (no

 

is poor.

high?

condensation).

Blinking in red

High temperature

zzIs the filter indicator lighted?

zzTurn off the MAIN POWER switch

inside.

 

using the procedure on page 40 and

(twice)

(Standby condition)

 

replace the ACF unit.

 

 

Blinking in red

Cooling fan has

zzTurn off the MAIN POWER switch

using the procedure on page 40 and

(3 times)

been stopped.

 

consult the dealer.

 

 

 

Note

zzIf no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.

JJFILTER indicator

Lamp

Information

Check point

 

Remedial measure

indication

 

 

 

 

 

 

The ACF unit has

zzCheck the [REMAINING

 

 

Lighting in red

FILTER] of [STATUS] in

zz

Replace the ACF unit.

run out.

[PROJECTOR SETUP] menu.

 

 

 

 

 

 

(Æpage 83)

 

 

Blinking in red

The ACF unit is not

zzCheck the ACF unit

zz

Replace the ACF unit.

installed.

compartment.

 

 

 

 

 

 

 

 

 

 

The ACF unit

 

 

 

 

remains few. The

zzCheck the [REMAINING

 

 

Lighting in

remaining use time

FILTER] of [STATUS] in

zzRequest the dealer to purchase the

orange

of the ACF unit is

[PROJECTOR SETUP] menu.

 

new ACF unit.

 

approximately 200

(Æpage 83)

 

 

 

hours.

 

 

 

Blinking in

The ACF unit cannot

zzIs foreign object blocking the

zzRemove the foreign object from the

 

ACF unit.

orange

operate properly.

ACF unit operation?

zzWhen the foreign object still

 

 

 

 

remained, contact the dealer.

Note

zzIf no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.

zzWhen the ACF unit is not installed, the filter indicator will blink in red and the power will turn off in 10 minutes. zzWhen the FILTER indicator is flashing green, the Auto Cleaning Filter (ACF) is normally rolling up. zzWhen the ACF unit is operating, operational sound may be heard.

zzThe usable time after lighting of the orange lamp may be shortened in a dusty environment. The time of about 200 hours is for reference only. Contact the dealer to purchase the new ACF unit earlier.

zzIf the projector is used at elevations higher than 1 400 m above sea level with the [HIGH ALTITUDE MODE] at [OFF], the lamp life or life of other components will be shortened.

zzBefore the FILTER indicator blinks in orange when operational malfunction, mechanical sound of the clutch may be heard. zzIf the Smoke Cut Filter is installed, the green lamp, which takes longer to turn ON/OFF, will flash.

zzIf the filter is running low, only one lamp lights even if [DUAL] is selected. The lamps will light as normal once the filter has been replaced and the residual filter has been reset.