Technical Information

Control commands via LAN

JJWhen WEB Control administrator rights password is set (Protect mode)

<Connection method>

1111 Obtain the IP address and port number (Initial set value = 1024) of the projector and make a request for connection to the projector.

You can obtain both IP address and port number from the menu screen of the projector.

IP address : Obtain from MAIN MENU [NETWORK] [NETWORK STATUS]

Port No. : Obtain from MAIN MENU [NETWORK] [NETWORK CONTROL] [COMMAND PORT]

2222 There is a response from the projector.

Response data

 

 

 

 

 

Data section

Blank

Mode

Blank

Random number

Termination

section

symbol

 

 

 

 

“NTCONTROL”

‘  ’

‘1’

‘  ’

“zzzzzzzz”

(CR)

(ASCII string)

0x20

0x31

0x20

(ASCII code hexadecimal

0x0d

 

 

 

 

number)

 

9 bytes

1 byte

1 byte

1 byte

8 bytes

1 byte

Mode :   1 = Protect mode

3333 Generate a 32-byte hash value from the following data using MD5 algorithm.

“xxxxxx:yyyyy:zzzzzzzz”

xxxxxx: Administrator rights user name for WEB CONTROL (Default user name is “admin1”)

yyyyy: Password of above administrator rights user (Default password is “panasonic”)

zzzzzzzz: 8-byte random number obtained in Step 2)

<Command transmission method>

Transmit using the following command format.

Transmitted data

 

Header

 

Data section

Termination

 

 

symbol

 

 

 

 

 

 

 

Hash value

 

‘0’

 

‘0’

Control command

(CR)

(See above

 

0x30

 

0x30

(ASCII string)

0x0d

<Connection method>)

 

 

 

 

 

 

 

32 bytes

 

1 byte

 

1 byte

Undefined length

1 byte

Receive data

 

 

 

 

 

 

 

 

Header

 

Data section

Termination

 

 

symbol

 

 

 

 

 

 

 

‘0’

 

‘0’

 

Control command

(CR)

0x30

 

0x30

 

(ASCII string)

0x0d

1 byte

 

1 byte

 

Undefined length

1 byte

Error response

 

 

 

 

 

 

 

 

 

Error message

 

 

Termination symbol

“ERR1”

Undefined control command

 

 

(CR)

“ERR2”

Out of parameter range

 

 

 

0x0d

“ERR3”

Busy state or no-acceptable period

 

 

 

“ERR4”

Timeout or no-acceptable period

 

 

 

“ERR5”

Wrong data length

 

 

 

 

“ERRA”

Password mismatch

 

 

 

 

 

 

4 bytes

 

 

 

1 byte

Appendix

ENGLISH - 115

Page 115
Image 115
Panasonic PT-DS8500E, PT-DS8500U Technical Information Control commands via LAN, There is a response from the projector