Appendix
Technical Information
PJLink protocol
The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform projector setting and projector status query operations from a computer.
JJControl commands
The following table lists the PJLink protocol commands that can be used to control the projector.
Command | Control details |
|
|
| Notes | |
|
| Parameters |
|
|
| |
POWR | Power supply control | 0 = Standby |
|
|
| |
|
| 1 = Power ON |
|
|
| |
|
| Parameters |
|
|
| |
POWR ? | Power supply status query | 0 = Standby | 1 = Power ON |
| ||
|
| 2 = |
| 3 = | ||
INPT | Input selection | Parameters |
|
|
| |
|
| 11 = RGB1 | 12 = RGB2 |
| 21 = VIDEO | |
INPT ? | Input selection query | 22 = | 31 = | 32 = HDMI | ||
|
| 33 = SDI | ||||
AVMT | Shutter control | Parameters |
|
|
| |
AVMT ? | Shutter mode query | 30 = Shutter mode off (picture mute canceled) | ||||
31 = Shutter mode on (picture mute) | ||||||
|
| |||||
|
| Parameters |
|
|
| |
|
| 1st byte : Indicates fan errors, range 0 - 2 | ||||
|
| 2nd byte : Indicates lamp errors, range 0 - 2 | ||||
|
| 3rd byte : Indicates temperature errors, range 0 - 2 | ||||
ERST ? | Error status query | 4th byte : Indicates cover open errors, range 0 - 2 | ||||
|
| 5th byte : Indicates filter errors, range 0 - 2 | ||||
|
| 6th byte : Indicates other errors, range 0 - 2 | ||||
|
| Definitions for each value from 0 to 2 are as follows. | ||||
|
| 0 = No error known 1 = Warning 2 = Error | ||||
|
| Parameters |
|
|
| |
|
| 1st digits (1 - 5 digits) : Lamp 1 cumulative operating time | ||||
LAMP ? | Lamp status query | 2nd digit : 0 = Lamp 1 off, 1 = Lamp 1 on | ||||
|
| 3rd digits (1 - 5 digits) : Lamp 2 cumulative operating time | ||||
|
| 4th digit : 0 = Lamp 2 off, 1 = Lamp 2 on | ||||
|
| The following are returned as parameters. | ||||
INST ? | Input selection list query | “11 12 21 22 31 32” | ||||
|
| “11 12 21 22 31 32 33” | ||||
NAME ? | Projector name query | The name set for [PROJECTOR NAME] in [NETWORK SETUP] is | ||||
returned. |
|
|
| |||
|
|
|
|
| ||
INF1 ? | Manufacturer name query | “Panasonic” is returned. |
|
| ||
INF2 ? | Model name query | “DZ8700”, “DS8500” or “DW8300” is returned. | ||||
INF0 ? | Other information query | Information such as version number is returned. | ||||
CLSS ? | Class information query | “1” is returned. |
|
|
|
JJPJLink security authorization
When using PJLink with security authorization, either of the password set for administrator privileges and the password set for user privileges with Web browser control can be used as the password for PJLink.
When using PJLink without security authorization, set use without the password for administrator privileges and the password for user privileges of Web browser control.
zzFor specifications regarding PJLink, refer to the Japan Business Machine and Information System Industries Association website.
URL http://pjlink.jbmia.or.jp/
114 - ENGLISH