![](/images/backgrounds/2957/2957-176101x1.png)
Chapter
When [MODE] of [BRIGHTNESS CONTROL SETUP] is set to [AUTO] and [LINK] is set from [GROUP A] to [GROUP D] The screen shows the status of the brightness control of synchronized projectors (up to eight units), including the projector being controlled through the
| BRIGHTNESS CONTROL STATUS |
|
| 1 | |||||
|
|
|
|
|
|
| |||
| LINK |
| GROUP A |
| |||||
|
|
|
|
| 2 | ||||
|
|
|
|
|
|
|
|
| 3 |
|
|
| PROJECTOR | 192. 168. 30. | 2 |
| |||
|
|
|
|
|
|
|
|
|
|
| 1: |
| PROJECTOR2 | 192. 168. 30. | 3 |
|
|
|
|
| 2: |
| PROJECTOR3 | 192. 168. 30. | 4 |
|
|
|
|
| 3: |
|
|
|
|
|
|
| 4 |
| 4: |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |||
| 5: |
|
|
|
|
|
|
|
|
| 6: |
|
|
|
|
|
|
|
|
| 7: |
|
|
|
|
|
|
|
|
| UPDATE |
|
|
| 5 | ||||
|
|
| MENU SELECT |
|
|
|
|
| 7 |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 |
When [MODE] of [BRIGHTNESS CONTROL SETUP] is set to [PC]
| BRIGHTNESS CONTROL STATUS |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| MODE | PC | 5 | |||||||
|
|
| PROJECTOR |
|
|
|
|
| 1 | |
|
|
|
|
|
|
|
| |||
| MENU RETURN |
|
|
|
|
| 6 | |||
|
|
|
|
|
| |||||
|
|
|
| |||||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
1Display the name of the projector.
2 Display the synchronized group.
3Display the IP address of the projector.
4Display the names and IP addresses of projectors in same group detected over the network.
5Display the status by color.
Green: There is an allowance for brightness correction.
Yellow: There is little allowance for brightness correction.
Red: There is a brightness control error.
6Display error detailed messages.
7Display error messages.
When the message [Failed to apply BRIGHTNESS CONTROL to some projectors.] appears, it means that synchronization with the projector displayed in red has failed.
Press as to select the projector displayed in red, and press the <ENTER> button to display the error details.
8Update to the latest status information.
rrError detailsError message | Measures to take | |
[Exceed maximum number of | ff Limit the number of projectors in one group to eight. | |
ff When synchronizing nine or more projectors, use the dedicated software “Multi Projector | ||
projectors.] | ||
Monitoring & Control Software”*1 through a computer. | ||
| ||
[Please check the COMMAND | ff Set [NETWORK CONTROL] → [COMMAND CONTROL] to [ON] for the projector in error. | |
CONTROL setting.] | ff Set [NETWORK CONTROL] → [COMMAND PORT] of all projectors to be linked to the same value. | |
[Please check the USER NAME | ff Assign the same [User name] and [Password] strings that have web control administrator rights to | |
and PASSWORD in the COMMAND | ||
CONTROL setting.] | all projectors to be linked. | |
| ||
[Cannot apply BRIGHTNESS |
| |
CONTROL .Please check projector | ff The projector is in standby. Switch on the power. | |
status.] |
| |
[Brightness Sensor Error] | ff There is a problem with the brightness sensor. If problems persist even after switching on the | |
power, consult your dealer. | ||
|
*1 “Multi Projector Monitoring & Control Software” is included in the supplied
Note
ff If the synchronized projectors are not displayed in the list, check the following: gg Are there devices with the same IP address on the network?
gg Are the LAN cables connected correctly? (x page 123) gg Are the subnets of the projectors the same?
gg Are the same [LINK] settings applied to a group?
ff Refer to [NETWORK SETUP] (x page 122) or “[Network config] page” (x page 131) on how to change the projector name.
ENGLISH - 101