Chapter 6Appendix — Technical information

PJLink security authentication

The password used for PJLink is the same as that of the password set for web control.

When using the projector without security authentication, do not set a password for web control.

ff For specifications related to PJLink, refer to the website of Japan Business Machine and Information System Industries Association. URL http://pjlink.jbmia.or.jp/english/

Using Art-Net function

Since the network function of the projector supports the Art-Net function, you can control the projector settings with the DMX controller and application software using the Art-Net protocol.

Channel definition

The following table lists the channel definitions used for controlling the projector with the Art-Net function.

Channel

Control details

Performance

Parameter

Remark

 

 

SHUTTER:OPEN

0‑63

 

1

Shutter control

No operation

 

64‑191

 

 

SHUTTER:CLOSE

192‑255

 

 

 

No operation

 

0‑7

 

 

 

RGB1

 

8‑15

 

 

 

RGB2

 

16‑23

 

 

 

VIDEO

 

24‑31

 

 

 

DVI‑D

 

32‑39

 

2

Input selection

HDMI

 

40‑47

SDI

 

48‑55

 

 

 

 

 

 

No operation

 

56‑127

 

 

 

Execute P IN P, USER1

128‑135

 

 

 

Execute P IN P, USER2

136‑143

 

 

 

Execute P IN P, USER3

144‑151

 

 

 

No operation

 

152‑255

 

 

 

No operation

 

0‑15

 

 

Lens H shift

 

16‑31

 

 

 

Lens V shift

 

32‑47

Operate together with “Lens

3

Lens function selection

Lens focus

 

48‑63

adjustment” of channel 4.

Lens zoom

 

64‑79

 

 

 

 

 

 

 

Move to the home position

80‑95

Operate together with “Execute

 

 

command action” of channel 4.

 

 

 

 

 

 

 

No operation

 

96‑255

 

 

 

(-) High speed

0‑31

 

 

 

Lens

(-) Low speed

32‑63

 

 

 

adjustment

(-) Fine

64‑95

 

 

 

 

adjustment

 

 

 

 

 

 

4

Lens control

Adjustment stop

96‑127

 

(+) Fine

128‑159

 

 

 

 

 

 

Lens

adjustment

 

 

 

 

 

 

 

adjustment

(+) Low speed

160‑191

 

 

 

 

(+) High speed

192‑223

 

 

 

Execute command action

224‑255

 

 

 

Standby

 

0‑63

 

5

Power supply control

No operation

 

64‑191

 

 

Power on

 

192‑255

 

 

 

100 %

 

0

Can be set in 256 steps between

6

Light volume adjustment

 

 

100 % and 0 %.

 

 

0 %

 

255

 

 

 

 

 

 

Operation not available

0‑127

When “Operation not available”

7

Lock

Operation available

128‑255

is set, operations of all channels

 

 

become unacceptable.

 

 

 

 

 