Chapter
Example of the
The following
=== Panasonic projector report(CONFIGURE) === | |||
Projector Type | : DZ16K |
| |
Serial No |
| : SW1234567 |
|
| |||
TEMPERATURE WARNING SETUP |
| ||
MINIMUM TIME | at [ 60] minutes interval | ||
INTAKE AIR TEMPERATURE | Over [ 46degC / 114degF ] | ||
ERROR | [ OFF ] |
| |
LAMP1 RUNTIME | [ OFF ] | at REMAIN [ 400] H | |
LAMP1 RUNTIME | [ OFF ] | at REMAIN [ 200] H | |
LAMP2 RUNTIME | [ OFF ] | at REMAIN [ 400] H | |
LAMP2 RUNTIME | [ OFF ] | at REMAIN [ 200] H | |
LAMP3 RUNTIME | [ OFF ] | at REMAIN [ 400] H | |
LAMP3 RUNTIME | [ OFF ] | at REMAIN [ 200] H | |
LAMP4 RUNTIME | [ OFF ] | at REMAIN [ 400] H | |
LAMP4 RUNTIME | [ OFF ] | at REMAIN [ 200] H |
INTAKE AIR TEMPERATURE |
| [ OFF ] |
|
| ||
PERIODIC REPORT |
|
|
|
| ||
Sunday | [ OFF ] | Monday | [ OFF ] | Tuesday | [ OFF ] | Wednesday [ OFF ] |
Thursday | [ ON ] | Friday | [ OFF ] | Saturday | [ OFF ] |
|
00:00 [ OFF ] 04:00 [ OFF ] 08:00 [ OFF ] 12:00 [ OFF ] 16:00 [ OFF ] 20:00 [ OFF ]
01:00 [ OFF ] 05:00 [ OFF ] 09:00 [ OFF ] 13:00 [ OFF ] 17:00 [ OFF ] 21:00 [ OFF ]
02:00 [ OFF ] 06:00 [ OFF ] 10:00 [ OFF ] 14:00 [ OFF ] 18:00 [ OFF ] 22:00 [ OFF ]
03:00 [ OFF ] 07:00 [ OFF ] 11:00 [ OFF ] 15:00 [ OFF ] 19:00 [ OFF ] 23:00 [ OFF ]
|
|
|
| ||
MAIN CPU BUS |
|
| [ | OK | ] |
FAN |
|
| [ | OK | ] |
INTAKE AIR TEMPERATURE | [ | OK | ] | ||
OPTICS MODULE TEMPERATURE | [ | OK | ] | ||
AROUND LAMP TEMPERATURE | [ | OK | ] | ||
LAMP1 REMAIN TIME |
| [ | OK | ] | |
LAMP2 REMAIN TIME |
| [ | OK | ] | |
LAMP3 REMAIN TIME |
| [ | OK | ] | |
LAMP4 REMAIN TIME |
| [ | OK | ] | |
LAMP1 STATUS |
|
| [ | OK | ] |
LAMP2 STATUS |
|
| [ | OK | ] |
LAMP3 STATUS |
|
| [ | OK | ] |
LAMP4 STATUS |
|
| [ | OK | ] |
[ | OK | ] | |||
[ | OK | ] | |||
INTAKE AIR TEMP.SENSOR | [ | OK | ] | ||
OPTICS MODULE TEMP.SENSOR | [ | OK | ] | ||
AROUND LAMP TEMP.SENSOR | [ | OK | ] | ||
BATTERY |
|
| [ | OK | ] |
LENS MOUNTER |
|
| [ | OK | ] |
BRIGHTNESS SENSOR |
| [ | OK | ] | |
ANGLE SENSOR |
|
| [ | OK | ] |
FILTER UNIT |
|
| [ | OK | ] |
AIR FILTER |
|
| [ | OK | ] |
AC POWER |
|
| [ | OK | ] |
(Error code 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00) | |||||
Intake air temperature | : 27 degC / | 80 degF |
| ||
Optics module temperature : 33 degC / | 91 degF |
| |||
Around lamp temperature | : 32 degC / | 89 degF |
| ||
PROJECTOR RUNTIME | 0 H |
|
|
| |
POWER ON |
| 0 times |
|
|
|
LAMP1 ON |
| 0 times |
|
|
|
LAMP1 |
| 0 H |
|
|
|
LAMP1 REMAIN |
| 3000 H |
|
|
|
LAMP2 ON |
| 0 times |
|
|
|
LAMP2 |
| 0 H |
|
|
|
LAMP2 REMAIN |
| 3000 H |
|
|
|
LAMP3 ON |
| 0 times |
|
|
|
LAMP3 |
| 0 H |
|
|
|
LAMP3 REMAIN |
| 3000 H |
|
|
|
LAMP4 ON |
| 0 times |
|
|
|
LAMP4 |
| 0 H |
|
|
|
LAMP4 REMAIN |
| 3000 H |
|
|
|
|
|
| |||
MAIN VERSION |
| 1.00 |
|
|
|
NETWORK VERSION | 1.00 |
|
|
| |
SUB VERSION |
| 1.00 |
|
|
|
LAMP STATUS |
| LAMP1=OFF LAMP2=OFF LAMP3=OFF LAMP4=OFF | |||
INPUT |
| RGB1 |
|
|
|
REMOTE2 STATUS | DISABLE |
|
|
| |
|
|
| |||
DHCP Client | OFF |
|
|
|
|
IP address | 192.168.0.8 |
|
|
| |
MAC address | 00:40:63:00:01:24 |
|
|
|
Tue Jan 07 17:20:39 2014
136 - ENGLISH