Chapter
Indicator status | Lighting in red | Blinking in red | Blinking in red | ||
(2 times) | (3 times) | ||||
|
|
| |||
Status | Internal temperature is high | Internal temperature is high | The cooling fan has | ||
(warning). | (standby status). | stopped. | |||
|
| ||||
| ff Did you turn on the power | ff Is the air intake/exhaust port blocked? |
| ||
Cause | when the temperature | ff Is the room temperature high? | ― | ||
was low (around 0 °C | |||||
| ff Is the filter indicator <FILTER> lit? |
| |||
| (32 °F))? |
| |||
|
|
|
| ||
|
| ff Remove any objects that are blocking the air intake/ |
| ||
| ff Wait up to 20 minutes in | exhaust port. |
|
| |
| the current status. | ff Install the projector in a location with the operating | ff Turn the <MAIN POWER> | ||
| ff Install the projector in a | environment temperature between 0 °C (32 °F) and | |||
| switch to <OFF> | ||||
Solution | location with the operating | 45 °C (113 °F)*1, and ambient humidity between 20 % | |||
(x page 50), and | |||||
| environment temperature | and 80 % (no condensation). | |||
| consult your dealer. | ||||
| between 0 °C (32 °F) and | ff Do not use the projector at high altitudes of 2 700 m | |||
|
| ||||
| 45 °C (113 °F)*1. | (8 858') or higher above sea level. |
| ||
|
| ff Clean or replace the air filter unit. (x page 143) |
|
*1 When using the projector at high altitudes (between 1 400 m (4 593') and 2 700 m (8 858') above sea level), the operating environment temperature should be between 0 °C (32 °F) and 40 °C (104 °F).
If you use the smoke cut filter, the operating environment temperature should be between 0 °C (32 °F) and 35 °C (95 °F). However, it cannot be used at high altitudes.
Note
ff If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
Filter indicator <FILTER>Indicator status |
| Lighting in red |
| Blinking in red | |
Status | The filter is clogged. |
|
| The air filter unit is not | |
The temperature inside or outside the projector is abnormally high. | attached. | ||||
| |||||
Cause | ff Is the air filter unit dirty? | ff Is the air intake/exhaust | ff Is [HIGH ALTITUDE | ff Is the air filter unit | |
port blocked? | MODE] set correctly? | attached? | |||
|
| ||||
|
|
| ff When using the projector |
| |
|
|
| at high altitudes between |
| |
|
|
| 1 400 m (4 593') and |
| |
|
| ff Remove any objects that | 2 700 m (8 858'), set |
| |
Solution | ff Clean or replace the air | [HIGH ALTITUDE MODE] | ff Attach the air filter unit. | ||
are blocking the air intake/ | |||||
| filter unit. (x page 143) | exhaust port. | (x page 96) to [ON]. |
| |
|
| ff Do not use the projector |
| ||
|
|
|
| ||
|
|
| at high altitudes of |
| |
|
|
| 2 700 m (8 858') or higher |
| |
|
|
| above sea level. |
|
Note
ff If the filter indicator <FILTER> is still lit or blinking after taking the measures, ask your dealer for repair.
ff If the filter is clogged while [LAMP SELECT] is set to [QUAD] or [TRIPLE], the setting may be forcibly changed to [DUAL]. To reset the setting, clean the air filter unit or replace it with a new one.
142 - ENGLISH