Chapter 6Appendix — Technical information

 

Data section

Blank

Mode

Blank

Random number section

Termination

 

symbol

 

 

 

 

 

 

Command

“NTCONTROL”

‘ ’

‘1’

‘ ’

“zzzzzzzz”

(CR)

example

(ASCII string)

0x20

0x31

0x20

(ASCII code hex number)

0x0d

Data length

9 bytes

1 byte

1 byte

1 byte

8 bytes

1 byte

ff Mode: 1 = Protect mode

3)Generate a 32-byte hash value from the following data using MD5 algorithm.

ff “xxxxxx:yyyyy:zzzzzzzz”

xxxxxxAdministrator rights user name for the web control (default user name is “admin1”)

yyyyyPassword of above administrator rights user (default password is “panasonic”)

zzzzzzzz8-byte random number obtained in Step 2)

Command transmission method

Transmit using the following command formats.

rrTransmitted data

 

Header

 

 

Data section

Termination

 

 

 

symbol

 

 

 

 

 

 

Command

Hash value

 

‘0’

‘0’

Control command

(CR)

example

(Refer to “Connecting” above)

 

0x30

0x30

(ASCII string)

0x0d

Data length

32 bytes

 

1 byte

1 byte

Undefined length

1 byte

rrReceived data

 

 

Header

Data section

Termination

 

 

symbol

 

 

 

 

 

Command

‘0’

 

‘0’

Control command

(CR)

example

0x30

 

0x30

(ASCII string)

0x0d

Data length

1 byte

 

1 byte

Undefined length

1 byte

rrError response

 

String

Details

 

“ERR1”

Undefined control command

 

“ERR2”

Out of parameter range

Message

“ERR3”

Busy state or no-acceptable period

“ERR4”

Timeout or no-acceptable period

 

 

“ERR5”

Wrong data length

 

“ERRA”

Password mismatch

Data length

4 bytes

Termination

symbol

(CR)

0x0d

1 byte

When web control administrator rights password is not set (Non-protect mode)

Connecting

1)Obtain the IP address and port number (Initial set value = 1024) of the projector and request for a

connection to the projector.

ff You can obtain both the IP address and the port number from the menu screen of the projector.

IP address

Obtain from the main menu [NETWORK] [NETWORK STATUS]

Port number

Obtain from the main menu [NETWORK] [NETWORK CONTROL] [COMMAND PORT]

2)Check the response from the projector.

ENGLISH - 159