Chapter
Lamp/temperature/filter indicators
When an indicator lights up
If a problem should occur inside the projector, the lamp indicators <LAMP1>/<LAMP2>/<LAMP3>/<LAMP4>, the temperature indicator <TEMP>, and the filter indicator <FILTER> will inform you by lighting or blinking. Check the status of the indicators and manage the indicated problems as follows.
Attention
ff When switching off the projector to deal with problems, make sure to follow the procedure in “Switching off the projector” (x page 50).
Lamp indicator <LAMP1>
Lamp indicator <LAMP2>
Lamp indicator <LAMP3>
Lamp indicator <LAMP4>
Temperature indicator <TEMP>
Filter indicator <FILTER>
Lamp indicators <LAMP1>/<LAMP2>/<LAMP3>/<LAMP4>
Indicator status | Lighting in red/lighting in | Blinking in red | Blinking in red | ||
orange*1 | (1 time) | (3 times) | |||
| |||||
Status | Time to replace the lamp | ff The lamp unit or the lamp | A problem is detected in the lamp or the power supply for | ||
unit. (x page 146) | case is not installed. | the lamp. |
| ||
|
| ||||
| ff Was [REPLACE LAMP] |
|
|
| |
| displayed when you |
|
| ff Some error has occurred | |
| turned on the power? |
| ff Have you turned on the | ||
Cause | ff Is the lamp unit or the | in the lamp circuit. Check | |||
ff The indicator lights up | power again immediately | ||||
lamp case installed? | for fluctuation (or drop) in | ||||
| when the runtime of the | after turning it off? | |||
|
| the source voltage. | |||
| lamp unit reaches 2 800 |
|
| ||
|
|
|
| ||
| hours. |
|
|
| |
|
| ff Install the lamp unit or |
|
| |
|
| the lamp case if it is not |
|
| |
|
| installed. | ff Wait a while until the | ff Turn the <MAIN POWER> | |
Solution | ff Replace the lamp unit. | ff If the indicator is still | luminous lamp cools | switch to <OFF> | |
blinking in red even when | off, and then turn on the | (x page 50), and | |||
|
| ||||
|
| having installed the lamp | power. | consult your dealer. | |
|
| unit or the lamp case, |
|
| |
|
| consult your dealer. |
|
|
*1 The indicator lights up in red while the lamp is turned off, and lights up in orange while the lamp is turned on.
Note
ff If the lamp indicators <LAMP1>/<LAMP2>/<LAMP3>/<LAMP4> are still lit or blinking after taking the measures, ask your dealer for repair.
ENGLISH - 141