Chapter
Channel | Control details | Performance | Parameter | Remark | |
|
| 0.0s | 0‑15 |
| |
|
| 0.5s | 16‑31 |
| |
|
| 1.0s | 32‑47 |
| |
|
| 1.5s | 48‑63 |
| |
|
| 2.0s | 64‑79 |
| |
|
| 2.5s | 80‑95 | Operate together with channel 1. | |
8 | 3.0s | 96‑111 | |||
| |||||
|
| 3.5s | 112‑127 |
| |
|
| 4.0s | 128‑143 |
| |
|
| 5.0s | 144‑159 |
| |
|
| 7.0s | 160‑175 |
| |
|
| 10.0s | 176‑191 |
| |
|
| No operation | 192‑255 | ― | |
|
| 0.0s | 0‑15 |
| |
|
| 0.5s | 16‑31 |
| |
|
| 1.0s | 32‑47 |
| |
|
| 1.5s | 48‑63 |
| |
|
| 2.0s | 64‑79 |
| |
|
| 2.5s | 80‑95 | Operate together with channel 1. | |
9 | 3.0s | 96‑111 | |||
| |||||
|
| 3.5s | 112‑127 |
| |
|
| 4.0s | 128‑143 |
| |
|
| 5.0s | 144‑159 |
| |
|
| 7.0s | 160‑175 |
| |
|
| 10.0s | 176‑191 |
| |
|
| No operation | 192‑255 | ― | |
10 | No operation | ― | ― | ― | |
|
| OFF | 0‑15 |
| |
|
| KEYSTONE | 16‑31 |
| |
11 | Geometric adjustment | CURVED | 32‑47 | ― | |
No operation | 48‑95 | ||||
|
|
| |||
|
| CORNER CORRECTION | 96‑111 |
| |
|
| No operation | 112‑255 |
|
Note
ff If the projector is operated with the remote control or on the control panel, or by the control command while controlling the projector using the
Control commands via LAN
When web control administrator rights password is set (Protect mode)
Connecting
1)Obtain the IP address and port number (Initial set value = 1024) of the projector and request for a
connection to the projector.
ff You can obtain both the IP address and the port number from the menu screen of the projector.
IP address | Obtain from the main menu → [NETWORK] → [NETWORK STATUS] |
Port number | Obtain from the main menu → [NETWORK] → [NETWORK CONTROL] → [COMMAND PORT] |
2)Check the response from the projector.
158 - ENGLISH