Command Line Interface (CLI)

AP-4000 Series User Guide

Parameter Tables

Syslog Parameters

The following parameters configure the Syslog settings.

Name

Type

 

Value

Access

CLI Parameter

Syslog

Group

N/A

R

syslog

Syslog Status

Integer

enable

RW

syslogstatus

 

 

disable (default)

 

 

Syslog Port

Octet String

514

R

syslogport

Syslog Lowest Priority

Integer

1

- 7

RW

syslogpritolog

Logged

 

1

= LOG_ALERT

 

 

 

 

2

= LOG_CRIT

 

 

 

 

3

= LOG_ERR

 

 

 

 

4

= LOG_WARNING

 

 

 

 

5

= LOG_NOTICE

 

 

 

 

6

= LOG_INFO (default)

 

 

 

 

7

= LOG_DEBUG

 

 

Heartbeat Status

Integer

enable (1)

RW

sysloghbstatus

 

 

disable (2) (default)

 

 

Heartbeat Interval

Integer

1

- 604800 seconds;

RW

sysloghbinterval

(seconds)

 

900 sec. (default)

 

 

NOTE: When Heartbeat is enabled, the AP periodically sends a message to the Syslog server to indicate that it is active. The frequency with which the heartbeat message is sent depends upon the setting of the Heartbeat Interval.

Syslog Host Table

The table described below configures the Syslog hosts that will receive message from the AP. You can configure up to ten Syslog hosts.

Name

Type

Value

Access

CLI Parameter

Syslog Host Table

Table

N/A

R

sysloghosttbl

Table Index

Integer

1 - 10

N/A

index

IP Address

IpAddress

User Defined

RW

ipaddr

Comment (optional)

DisplayString

User Defined

RW

cmt

Status (optional)

Integer

enable

RW

status

 

 

disable

 

 

 

 

delete

 

 