Other Messages
Warning Message | Description |
|
|
Cleaning Request | The AIT drive needs cleaning. Refer to “Cleaning the AIT |
| |
|
|
Cleaning Tape at EOM | The spent cleaning cartridge is set. Replace the spent |
| cleaning cartridge with a new one. |
|
|
Clean failure | Cleaning failed. Repeat the cleaning procedure. |
|
|
When the following messages appear, perform the prescribed actions.
Warning Message | Description |
|
|
Drive information | If the XX code is 3x, 4x, 5x, or 72, insert a new AIT data |
XX | cartridge into the library after cleaning the drive.* |
| For details, refer to “Cleaning the AIT Drive” (page 63). |
| If the XX code is CE, see the explanation below. |
| If the XX code is a code other than those explained |
| above, contact your dealer. |
|
|
Drive information | The cleaning cartridge is exhausted. Replace it with a |
CE | new one and clean the drive again. |
or |
|
Cleaning Tape at EOM |
|
|
|
Please check the | The transport screw may still be fastened in place. Refer |
transport screw | |
|
|
*If the message “Drive information F8” appears on the display, the cartridge being used may not be the correct one. Check the type of cartridge being used. To remove the loaded cartridge, select “3. Move Tape” in the menu and move the cartridge from the drive to the library slot. Select “2. Eject/Insert Tape”, and then “1. Eject from Library” to remove the cartridge.
When the following messages appear, contact your dealer.
Warning Message | Description |
|
|
Threshold condition | The turn table has operated more than the specified |
Turn Table | number of times. |
|
|
Threshold condition | The slider has operated more than the specified number |
Slider | of times. |
|
|
Threshold condition | The picker has operated more than the specified number |
Picker | of times. |
|
|
Threshold condition | The shutter has operated more than the specified number |
Shutter | of times. |
|
|
Threshold condition | The cartridges have loaded in the drive more than the |
Drive Load | specified number of times. |
|
|
Threshold condition | The fan has operated more than the specified number of |
Fan | times. |
|
|
Fan 1 trouble | Fan 1 malfunction. |
|
|
Fan 2 trouble | Fan 2 malfunction. |
|
|
Fan 3 trouble | Fan 3 malfunction. |
|
|
Fan | Fan 1, Fan 2 and Fan 3 malfunction. |
|
|
Appendix 100