Other Messages

Warning Message

Description

 

 

Cleaning Request

The AIT drive needs cleaning. Refer to “Cleaning the AIT

 

Drive” (page 63).

 

 

Cleaning Tape at EOM

The spent cleaning cartridge is set. Replace the spent

 

cleaning cartridge with a new one.

 

 

Clean failure

Cleaning failed. Repeat the cleaning procedure.

 

 

When the following messages appear, perform the prescribed actions.

Warning Message

Description

 

 

Drive information

If the XX code is 3x, 4x, 5x, or 72, insert a new AIT data

XX

cartridge into the library after cleaning the drive.*

 

For details, refer to “Cleaning the AIT Drive” (page 63).

 

If the XX code is CE, see the explanation below.

 

If the XX code is a code other than those explained

 

above, contact your dealer.

 

 

Drive information

The cleaning cartridge is exhausted. Replace it with a

CE

new one and clean the drive again.

or

 

Cleaning Tape at EOM

 

 

 

Please check the

The transport screw may still be fastened in place. Refer

transport screw

to “Unpacking” (page 13).

 

 

*If the message “Drive information F8” appears on the display, the cartridge being used may not be the correct one. Check the type of cartridge being used. To remove the loaded cartridge, select “3. Move Tape” in the menu and move the cartridge from the drive to the library slot. Select “2. Eject/Insert Tape”, and then “1. Eject from Library” to remove the cartridge.

When the following messages appear, contact your dealer.

Warning Message

Description

 

 

Threshold condition

The turn table has operated more than the specified

Turn Table

number of times.

 

 

Threshold condition

The slider has operated more than the specified number

Slider

of times.

 

 

Threshold condition

The picker has operated more than the specified number

Picker

of times.

 

 

Threshold condition

The shutter has operated more than the specified number

Shutter

of times.

 

 

Threshold condition

The cartridges have loaded in the drive more than the

Drive Load

specified number of times.

 

 

Threshold condition

The fan has operated more than the specified number of

Fan

times.

 

 

Fan 1 trouble

Fan 1 malfunction.

 

 

Fan 2 trouble

Fan 2 malfunction.

 

 

Fan 3 trouble

Fan 3 malfunction.

 

 

Fan 1-3 trouble

Fan 1, Fan 2 and Fan 3 malfunction.

 

 