At the status display, press the [MENU] button for two seconds.

Moving the Cartridges

It is possible to move a cartridge from a slot to the AIT drive or vice versa. Set the cartridge in the slot before performing the procedure below. When moving a cartridge, specify the slot with the element address. For information about element addresses, refer to “Assigned Element Addresses” (page 48) in Chapter 3, “Basic Usage”.

Notes

It is not possible to move a cartridge between slots. When you want to set a cartridge in a different slot, first remove the cartridge, then set it in a different slot.

It is not possible to remove a cartridge directly from the AIT drive. Perform the procedure below, move the cartridge to the desired slot, and then remove it.

1

2 Use the V and v buttons to select “3.Move Tape”, then press the [ENTER] button.

3 Use the V and v buttons to set the element address of the slot that has the moving source cartridge, then press the [ENTER] button.

Note

“DR” indicates an AIT drive.

Source DR Destination 01

4 Use the V and v buttons to set the element address of the destination slot, then press the [ENTER] button.

5 When “[ENTER] to activate” appears, press the [ENTER] button.

The cartridge moves to a new slot, and the display returns to the menu.

Source DR

Destination 01

[ENTER] to activate

6 Press the [CANCEL] button to return to the status display.

Viewing Information Related to the AIT Library

Using the Information Menu of the control panel, the following information related to the AIT library can be viewed:

Vendor ID

Product name

Serial number

Version

Note

Information related to the AIT library can also be viewed through a browser.

Chapter 4 Operating the AIT Library

59