Two or more inserted cartridges
The element address of the front slot appears on the first line. The element address of the next slot appears on the second line.
1 Eject the cartridge and press the [ENTER] button.
2 The slot moves to the next. Eject the cartridge in the same manner and press the [ENTER] button.
When you press the [ENTER] button, the slot moves to the next.
3 Repeat until all the cartridges are ejected, and then press the [CANCEL] button.
Eject Tape Slot 01
Next Slot 02
[CANCEL] to exit
[ENTER] to next slot
Only one inserted cartridge
The element address of the front slot appears on the first line. (Nothing appears on the second line.)
1 Eject the cartridge and press the [CANCEL] button.
Eject Tape Slot 01
[CANCEL] to exit
Caution
Do not put your fingers in the slot when it is moving, as this could result in injuries.
10 When “[ENTER] to activate” appears, press the [ENTER] button.
If you selected “1. Single Mode” in step 4, the display on the right appears.
Slot 01
Exit ?
[ENTER] to activate
If you selected “2. Multiple Mode” in step 4, the display on the right appears.
Eject Tape Slot 01 Exit ?
[ENTER] to activate
The shutter closes and the |
| ||
Slot 01 | |||
initialization is performed. | |||
| |||
|
| Initializing | |
|
| ||
Caution |
|
| |
Keep your fingers clear of the |
| ||
shutter when it closes. |
|
11 When the initialization ends, press the [CANCEL] button three times to return to the status display.
Replacing the Cartridges
When replacing a cartridge, specify the slot using the element address. For information about element addresses, refer to “Assigned Element Addresses” (page 48) in Chapter 3, “Basic Usage”.
Chapter 4 Operating the AIT Library | 53 |
|
|