Technical Notes A

Specifications

Printer tilt

Place the printer on a level surface with no more than 3° tilt in any direction. Equivalent to raising one corner of the printer approximately 2 cm

(0.75 inches.)

Caution Tilting the printer more than 3° causes drum fluid to leak from the maintenance tray resulting in damage to your printer not covered by the printer’s warranty.

Temperature

Operating: 10° C to 35° C (50° F to 95° F)

Nonoperating: –30° C to +60° C (–22° F to 140° F)

Storage: –30° C to +60° C (–22° F to 140° F)

Humidity

Operating: 10% to 80% Relative Humidity, noncondensing

Nonoperating: 10% to 95% Relative Humidity, noncondensing

Altitude

Operating: 0 to 2,400 meters (0 to 8,000 feet)

Nonoperating: 0 to 15,000 meters (0 to 50,000 feet)

Primary voltage ranges (switch-selectable)

87 – 128 VAC, 115 VAC nominal

174 – 250 VAC, 220 VAC nominal

Frequency range

 

 

48 to 66 Hz

 

 

AC input ratings

 

 

115 VAC, 10 Amps

220 VAC, 5 Amps

Printing resolution and speed*

300 x 300 dpi color print on paper: 4 pages per minute

300 x 300 dpi color print on transparency: 2 pages per minute

600 x 300 dpi color print on paper: 2 pages per minute (optionally available)

* Left and right margins set to 0.3 in. (7.4 mm) or larger.