Explanation

o:Fine adjustment direction for the ribbon back tension motor voltage +: Positive (The voltage is raised.)

-: Negative (The voltage is lowered.)

pp:Fine adjustment value for the ribbon back tension motor voltage Fine adjustment direction is “+”:

00 to 10 (in units of 1 step) Fine adjustment direction is “-”: 00 to 15 (in units of 1 step)

qq:Lower reflective sensor manual threshold fine adjustment value 00 to 40 (in units of 0.1 V)

rr:Transmissive sensor manual threshold fine adjustment value 00 to 40 (in units of 0.1 V)

(1)This command is not executed until the printer enters an idle state.

(2)Except for some of them, the parameters set by this command become effective when the power is turned on or the Reset Command is sent.

*1: The value can be set in units of 0.1 mm. However, the value which is actually set on the printer, is in units of 0.5 mm. When a value from 0.0 mm to 0.4 mm is set, it is actually set on the printer as 0.0 mm. Also when a value from 0.5 mm to 0.9 mm is set, it is actually set on the printer as 0.5 mm.

- 193 -

Page 197
Image 197
Toshiba B-850 manual