(4)Type of check digit

c Where no check digit is attached, the bar code of the data row will be drawn.

d In the case of the check digit check, if each check digit checked according to the type of bar code is normal, the bar code will be drawn. If the check digit not meeting the requirement is designated, the bar code will not be drawn.

e In the case of the check digit auto attachment, each check digit is attached according to the type of bar code and the bar code is drawn.

f If the type of bar code is CODE93, CODE128 (with auto code selection), or UCC/EAN128, the check digit will always be attached regardless of the designation of the type of check digit.

g If the type of bar code is JAN, EAN, or UPC, the designation of no check digit attachment automatically assume the check digit check.

h DBP Modulus 10 is Modulus 10 for Deutsche Bundespost Postdienst only.

(5)Bar width, space width, and character-to-character space

Designate the bar, space, and character-to-character space widths according to the type of bar code. Note that the proper value to be designated differs according to the rotational angle of bar code, type, number of digits, print speed, paper used, etc. Examples of such designations are listed below. (1 dot = 1/12 mm)

In the case of JAN, EAN, UPC, CODE93, CODE128, UCC/EAN128, PDF417, or MicroPDF417, a 2 to 6-module width is automatically calculated when a 1-module width is designated.

Type of bar code

1 module

 

2 modules

 

3 modules

4 modules

5 modules

6 modules

 

Bar

Space

 

Bar

Space

 

Bar

Space

Bar

Space

Bar

Space

Bar

Space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JAN, EAN, UPC

4

 

 

 

 

8

 

 

 

 

12

16

-

-

CODE93

3

 

 

 

 

6

 

 

 

 

9

12

-

-

CODE128, EAN128

3

 

 

 

 

6

 

 

 

 

9

12

-

-

PDF417

3

 

 

 

 

6

 

 

 

 

9

12

15

18

MicroPDF417

2

 

 

 

 

4

 

 

 

 

6

8

10

12

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of bar code

 

 

Narrow

 

Wide

 

Character-to-character

 

 

 

 

 

Bar

Space

 

Bar

Space

 

 

space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MSI

 

3

 

3

 

8

 

8

 

 

0

 

 

 

 

ITF

 

3

 

3

 

8

 

8

 

 

0

 

 

 

 

CODE39

 

3

 

3

 

8

 

8

 

 

3

 

 

 

 

NW7

 

3

 

3

 

8

 

8

 

 

3

 

 

 

 

Industrial 2 of 5

 

3

 

3

 

8

 

0

 

 

3

 

 

 

 

When NW7 is used, transmission of the space character assumes the space of (narrow space width × 12) dots. In this case, the space is max. 255 dots.

In the case of Data Matrix

1-cell width

1-cell width = 3

When 1-cell width is “00” for the Data Matrix, a two-dimensional code is not drawn. However, the two-dimensional code printed on the previous label is cleared.

- 96 -

Page 100
Image 100
Toshiba B-850 manual JAN, EAN, UPC CODE93, Type of bar code Narrow Wide Character-to-character, MSI ITF CODE39 NW7