~In the case of QR code (Two-dimensional code)

Format

c [ESC] XBaa; bbbb, cccc, d, e, ff, g, h (, Mi) (, Kj) (, Jkkllmm) (= nnn --- nnn) [LF] [NUL]

Term

d[ESC] XBaa; bbbb, cccc, d, e, ff, g, h (, Mi) (, Kj) (, Jkkllmm) (= oo1, oo2, oo3 ------ oo20) [LF] [NUL]

aa:Bar code number 00 to 31

bbbb:Print origin of X-coordinate of the bar code Fixed as 4 digits (in 0.1 mm units)

cccc:Print origin of Y-coordinate of the bar code 4 or 5 digits (in 0.1 mm units)

d:Type of bar code

T:QR code (Two-dimensional code)

e:Designation of error correction level

L:High density level

M:Standard level

Q: Reliability level

H:High reliability level

ff:1-cell width

00 to 52 (in dots)

g:Selection of mode

M:Manual mode A : Automatic mode

h:Rotational angle of the bar code

0:

1:90°

2:180°

3:270°

Mi:

Selection of model

 

(Omissible. If omitted, Model 1 is automatically selected.)

 

i = 1: Model 1

 

2: Model 2

Kj:

Mask number

 

(Omissible. If omitted, the number is automatically set.)

 

j = 0 to 7:

Mask number 0 to 7

 

8:

No mask

Jkkllmm: Connection setting

(Omissible. No connection if this parameter is omitted.)

kk=01 to 16: Value indicating which divided code is connected.

ll= 01 to 16: Number of divided codes

mm= 00 to FF: A value for all data to be printed, to which XOR is applied in units of bytes (Not divided)

nnn--- nnn: Data string to be printed (Omissible) Max. 2000 digits

oo1 --- oo20: Link field No. (Omissible)

01 to 99 (1 to 99 can also be used.)

Up to 20 digits can be designated using commas.