2.1.5 ORIGINAL SIZE DETECTION

[G]

[F]

[A]

[B]

[C]

[D]

[E]

The ADF detects the original size by combining the readings of original length sensor [A], and original width sensors-1 [B], -2 [C], and -3 [D].

Original Length

The original length sensor and the disk [E] (connected to the transport roller) generate a pulse signal. The CPU counts pulses, starting when the leading edge of the original turns on the registration sensor [F], until the trailing edge of the original turns off the entrance sensor [G].

Original Width

The CPU detects original width using three original width sensors -1, -2, -3 as shown above. Three small circles on the diagram indicate the positions of the sensors.

Original Width Sensor Location

A 4 SEF

B 4/B5 LEF

D LT/LT LEF

A 3/A4 LEF

Detectable Paper Sizes

Please refer to the “1.2 ADF” table in “Specifications”.