7.8.2 JOGGER UNIT DRIVE

 

[F]

[C]

 

[B]

 

 

[A]

[G]

 

[D]

 

 

[H]

 

 

[J]

[I]

[E]

At prescribed intervals, the jogger motor [A] switches on and drives the jogger timing belt [B], gear [C] and jogger fence timing belt [D] which drives the shift jogger fences [E] against the sides of the stack to align its edges.

At the end of the job, the jogger fence lift motor [F] switches on and raises the fences until the actuator [G] leaves the slot of the shift jogger fence lift HP sensor [H] and shuts off the shift jogger fence lift motor.

At the same time, the jogger motor reverses and drives the fences away from the sides of the stack until the actuator [I] deactivates the shift jogger fence HP sensor [J] and switches off the jogger motor.

The jogger fences remain up in the standby position until the next job starts.

PTM

7-27

B070/B071

Page 202
Image 202
Toshiba E-STUDIO900 manual Jogger Unit Drive