Original Exit (Double-Sided Original Mode)
[C]
[E]
[A]
[B]
[D]
The exit gate solenoid [A] turns on and the exit gate [B] opens.
The inverter gate solenoid [C] remains off, and the original is fed out to the upper tray. The transport belt motor turns off when the trailing edge of the original passes the exit sensor [D].
To stack the originals neatly on the upper tray, the
PTM | B070/B071 |