2.6.5 DEVELOPMENT BIAS
[A]
[B] | [C] |
[D]
The CBG (Charge Bias Grid) power pack [A] applies the negative development bias (- 550V) to both the lower sleeve roller and upper sleeve roller through the receptacles [B] and the sleeve roller shafts [C].
The development bias prevents toner from being attracted to the
The development rollers [D] employ fixed shafts that do not rotate. This eliminates friction on the shafts so they never require lubrication.
PTM | B070/B071 |