Toshiba E-STUDIO900 manual Cleaning Blade Pressure and Side-to-Side Movement

Models: E-STUDIO900

1 224
Download 224 pages 42.29 Kb
Page 69
Image 69

Cleaning Blade Pressure and Side-to-Side Movement

[C]

[D]

[B]

[A]

The spring [A] always pushes the cleaning blade against the drum. The cleaning blade pressure can be manually released by pushing up the release lever [B]. To prevent cleaning blade deformation during transportation, the release lever must be locked in the pressure release (upper) position.

The guide roller [C] at the rear end of the cleaning blade holder touches the cam gear [D], which moves the blade from side to side. This movement helps to disperse accumulated toner to prevent early blade edge wear.