Toshiba E-STUDIO900 manual Original Exit Single-Sided Original Mode

Models: E-STUDIO900

1 224
Download 224 pages 42.29 Kb
Page 35
Image 35

Original Exit (Single-Sided Original Mode)

[B]

[A]

[C]

The exit gate solenoid [A] remains off, the exit gate [B] remains closed, and the original is fed out to the right exit tray.

The speed of the motor is reduced about 30 mm from the trailing edge of the original to ensure the originals stack neatly on the exit tray. This timing is determined by the length of the original, and the time since the exit sensor [C] detected the leading edge.

The transport belt motor turns off after the exit sensor [C] turns off.

PTM

2-10

B070/B071

Page 35
Image 35
Toshiba E-STUDIO900 manual Original Exit Single-Sided Original Mode