2.12.4 AUTO OFF MODE
Auto off mode is used only if no optional printer/scanner unit is installed.
Entering auto off mode
The machine enters auto off mode when one of the following is done.
•The auto off timer runs out after the last job (User Tools – System Settings – Timer Setting – Auto Off Timer: default setting is 90 min)
•The operation switch is pressed to turn the power off
What happens in auto off mode
When the machine enters auto off mode, the fusing lamps and all dc supplies except +5VE/12VE (+5V/12V for energy saver mode) turn off.
Returning to stand-by mode
The machine returns to
Operation | Energy |
| Approx. | System |
| |
Fusing Temp. | Recovery | Note | ||||
Switch | Saver LED | +5V | ||||
| Time |
| ||||
|
|
|
|
| ||
|
| Room Temp. |
|
| Only +5VE/+12VE is | |
Off | Off | (Fusing lamp off) | 360 s | Off | supplied to the | |
|
|
|
|
| Controller, MB, HDD. | |
|
|
|
|
|
|
Disabling auto off mode
If the user wishes to disable auto off mode, use the following user tool: User Tools – System Settings – AOF (change the setting to ‘OFF’).
PTM | B070/B071 |