(13)Remove 2 screws, and remove the arm to take off the transport path switching solenoid.

Notes:

When installing, perform adjustment for both cases in which the solenoid is turned ON and OFF.

1.When the solenoid is turned OFF, the gap between the surface of the transport guide and the upper side of the flap edge must fall within 1.5 mm to 2.1 mm. Fix the solenoid with 2 screws.

2.When the solenoid is turned ON, the gap between the surface of the transport guide and the upper side of the flap edge must fall within 2.3 mm to 2.9 mm. Fix the solenoid with 2 screws.

© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved

Arm

4

Transport path switching solenoid

Fig. 4-249

 

 

Surface of the

Upper side of

 

 

transport guide

the flap edge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5mm to 2.1mm

Fig. 4-250

Upper side of

the flap edge

2.3mm to 2.9mm

Surface of the transport guide