(3)Remove 2 screws, and then take off the sen- sor rail.

Note:

When installing the movable tray drive unit, fix it at the position where the gap between the center mark of the scale on the sensor rail and the edge of the movable tray posi- tion-a sensor is from 0 to 1 mm. Be sure to adjust the installation position by shifting the movable tray shift frame and measure the positions at the upper and lower measuring points on the sensor rail as shown in the fig- ure.

Sensor rail

Fig. 4-284

Sensor rail

Sensor

Measure

0mm to 1.0mm

Fig. 4-285

4

(4)Release the latch, and then disconnect the connectors to take off the movable tray posi- tion-a sensor, movable tray position-B sen- sor and movable tray position-c sensor.

Movable tray position-A sensor

Movable tray position-B sensor

Movable tray position-C sensor

Fig. 4-286

© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved

MJ-1103/1104

 

DISASSEMBLY AND INSTALLATION

4 - 101

Page 169
Image 169
Toshiba MJ-1103, MJ-1104 service manual Sensor rail