CAT System Computer Control

Opcode Command Chart (1)

 

Command

Parameter Bytes

Opcode

Parameter Description

 

 

 

 

 

 

 

 

 

or Key

1st

2rd

3rd

4th

5th

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPLIT

T

01H

Split Tx/Rx operation ON (T = 01H) or OFF (T = 00H)

 

 

 

 

 

 

 

 

 

 

 

Recall

X

02H

Recalls memory number X: 01H ~ 71H, corresponding to

 

 

Memory

memories 1 ~ 99, P1 ~ P9, and QMB 1 ~ QMB 5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VFO/MEM

X

03H

Enter (K = 00H), Mask (K = 01H) or Un-Mask (K = 02H),

 

 

memory channel X (01H ~ 71H).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tuning knob Lock/Unlock:

 

 

 

LOCK

P

04H

P = 00H: Main Dial Lock

P = 01H: Main Dial Unlock

 

 

 

 

 

 

 

 

P = 02H: Sub Dial Lock

P = 03H: Main Dial Unlock

 

 

 

 

 

 

 

 

 

 

 

A/B

V

05H

Select VFO-A (V = 00H), or VFO=B (V = 01H).

 

 

 

 

 

 

 

 

 

 

 

[MuB]

X

06H

Copy memory X (01H ~ 71H) to last-used VFO.

 

 

 

 

 

 

 

 

 

 

 

 

UP (p)

U

V

07H

Step VFO-A/B (V = 00H/01H) up

 

 

 

by 100 kHz/1 MHz (U = 00H/01H).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN (q)

D

V

08H

Step VFO-A/B (V = 00H/01H) down

 

 

 

by 100 kHz/1 MHz (D = 00H/01H).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clarifier offset direction & frequency in BCD

 

 

 

 

 

 

 

 

C1 = Hz offset

(C1 = 00H ~ 99H)

 

 

 

 

 

 

 

 

 

C2 = kHz offset

(C2 = 00H ~ 09H)

 

 

 

CLAR

C1

C2

C3

C4

09H

C3 = Hz offset

(C3 = 00H/FFH)

 

 

 

Clarifier On/Off/Reset:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C4 = RX CLAR ON/OFF (C4 = 00H/01H)

 

 

 

 

 

 

 

 

TX CLAR ON/OFF (C4 = 80H/81H)

 

 

 

 

 

 

 

 

CLAR CLEAR

(C4 = FFH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Main

 

 

 

 

 

New operating frequency in BCD format (F1 ~ F4)

 

 

VFO-A

F1

F2

F3

F4

0AH

 

 

see text for formatting example.

 

 

 

Operating Freq.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select Operating Mode M:

 

 

 

 

 

 

 

 

 

LSB: M = 00H

USB: M = 01H

CW: M = 02H

 

 

MODE

M

0CH

CW (R): M = 03H

AM: M = 04H

AM(Sync): M = 05H

 

 

 

 

 

 

 

 

FM: M = 06H

FM-W: M = 07H

RTTY (L): M = 08H

 

 

 

 

 

 

 

 

RTTY (U): M = 09H PKT (L): M = 0AH PKT (F): M = 0BH

 

 

 

 

 

 

 

 

 

 

 

Pacing

N

0EH

Add N-millisecs (00H ~ FFH) delay between each byte of all

 

 

downloaded data returned from the transceiver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTT

T

0FH

Transmitter ON (T = 01H) or OFF (T = 00H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructs the radio to return 1, 16, 32, or 1863 bytes of Sta-

 

 

 

 

 

 

 

 

tus Updata data. X is significant only when U = 1 ~ 4.

 

 

 

 

 

 

 

 

X = 00H ~ 71H: desired memory channel

 

 

Status

X

U

10H

(1 ~ 99, P1 ~ P9, or QMB 1 ~ QMB 5)

 

 

 

 

 

 

 

 

Update

 

 

 

 

 

U = 00H All 1863 byte

 

 

 

 

 

 

 

 

 

 

U = 01H 1-byte Memory Channel Number

 

 

 

 

 

 

 

 

U = 02H 16-byte Operating Data

 

 

 

 

 

 

 

 

 

U = 03H 2 x 16-byte VFO (A & B) Data

 

 

 

 

 

 

 

 

 

U = 04H 1 x 16-byte Memory Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

page 94

MARK-V FT-1000MP Operating Manual

Page 96
Image 96
Vertex Standard FT-1000MP manual Opcode Command Chart, 0AH, 0CH, 0EH, 0FH