Vertex Standard FT-1000MP manual Bandwidth Buttons NOR/NAR1/NAR2 Buttons, NB Button, NOR NAR Mode

Models: FT-1000MP

1 119
Download 119 pages 809 b
Page 30
Image 30

FRONT PANEL CONTROLS

48. BANDWIDTH Buttons (NOR/NAR1/NAR2) Buttons

These three buttons select the 2nd and 3rd IF fil- ters for the receiver (except in the FM mode). The LED inside each button glows red when the corresponding bandwidth is selected.

The available 2nd and 3rd IF filters are as follows:

49.NB Button

Pressing this button activates the IF Noise Blanker, which may help reduce many different types of man- made impulse noise (but not atmospherics). When the Noise Blanker is activated, the LED inside button will glow red.

You can select the Noise Blanker Type (for short- duration pulses or for long-duration pulses) and its blanking level via menu selection 2-8.

2nd and 3rd IF Filter Bandwidth

 

 

NOR

NAR 1

NAR 2

 

 

MODE

2nd IF

3rd IF

2nd IF

3rd IF

2nd IF

3rd IF

 

 

 

(8.2MHz)

(455 kHz)

(8.2MHz)

(455 kHz)

(8.2MHz)

(455 kHz)

 

 

SSB

2.4 kHz/ATTø1

2.4/6.0 kHzø1

2.0 (2.4) kHz

2.0 (2.4) kHz

N/A (2.0 kHz)

N/A (2.0 kHz)

 

 

CW

2.0/2.4 kHzø2

2.0/2.4 kHzø2

500 Hz

500 Hz

250 Hz

250 Hz

 

 

AM

ATT

6.0 kHz

2.4 kHz

2.4 kHz

2.0 kHz

2.0 kHz

 

 

RTTY/PKT/USER

2.4 kHz

2.4 kHz

2.0 kHz

2.0 kHz

250/500 Hzø3

250/500 Hzø3

 

ø1: You can select the bandwidth via menu selection 5-0. The first value (bandwidth) is factory default.

ø2: You can select the bandwidth via menu selection 5-2. The first value (bandwidth) is factory default.

ø3: You can select the bandwidth via menu selection 5-4. The first value (bandwidth) is factory default.

Note 1 - In the factory default condition, the SSB NAR 1 bandwidth is “2.0 kHz/2.0 kHz (2nd IF/3rd IF)” and the SSB NAR 2 bandwidth is disabled. If you set the SSB NOR bandwidth to “ATT/6.0 kHz (2nd IF/3rd IF)” via menu selection 5- 0, the NAR 1 bandwidth will be set to “2.4 kHz/2.4 kHz (2nd IF/3rd IF)” and the NAR 2 bandwidth will be set to “2.0 kHz/ 2.0 kHz (2nd IF/3rd IF)” automatically.

Note 2 - The 2nd IF (8.2 MHz) 2.0-kHz BW filter (Yaesu P/N YF-114SN) and 250 Hz BW filter (Yaesu P/N YF-114CN) and 3rd IF (455 kHz) 2.0-kHz BW filter (Yaesu P/N YF-110SN), 500 Hz BW filter (Yaesu P/N YF-115C) and 250 Hz BW filter (Yaesu P/N YF-110CN) are option.

Note 3 - The Sub Receiver use a double-conversion circuit with 47.21 MHz and 455 kHz intermediate frequencies. Both the 6.0 kHz and 2.4 kHz filters are selected automatically according to mode, and with the optional 500 Hz Collins me- chanical filter (Yaesu P/N YF-115C) installed and enabled via menu programming, it can be selected for CW operation.