Menu Selection and Settings
0-8 Auto-uP
Auto Channel Up - When programming memo- ries from the VFO, this feature automatically increments selection to the next higher memory channel. This al- lows programming sequential memories more easily (you don’t have to manually select the next memory to be written). This also prevents inadvertently overwrit- ing stored memories.
0-9 EdSP
EDSP on/off - Enables/Disables the EDSP feature. This parameter should always be set to “On” unless you have a compelling reason not to use the EDSP system.
1-0 diAL-SPd
VFO A & B Dial FAST Tuning Rate - Selects x2 or
x4 tuning when the [FAST] button is pressed.
1-1 SJ-SPEEd
Shuttle Jog Encoder Speed - Selects the encoder pulse duration from 1 ~ 100 msec (in 1 msec steps).
1-7 AutoFASt
Automatic Selecting of AGC recovery time -
When the front panel AGC selector is set to the “AUTO” position and this feature is “ON,” the AGC decay time automatically is set to “FAST” during the following op- erating situations:
¦During scanning;
¦In 250/500 Hz bandwidth; and
¦When you turn the VFO Knob for more than ½- second.
1-8 cLAr-tun
Clarifier Tuning Offset - Enables/disables the off- set tuning meter above the Main VFO frequency dis- play. As the [CLAR] control is rotated and the TX or RX frequency is offset, a single meter segment shifts to show your relative offset from the original frequency.
1-9 cLAr-StP
Clarifier Tuning Step Size - Selects 0.625 Hz, 1.25 Hz, 2.5 Hz, 5 Hz, 10 Hz, or 20 Hz tuning steps used with the RX and TX CLAR control.
1-2 SFt-StEP
IF SHIFT/WIDTH Control Tuning Step Size - Se- lects 10 or
1-3 A-StEP
MAIN
SUB
1-5 cH-StEP
VFO Channel Step Size - For the Channel Step- ping feature, step size can be selected from 1 ~100 kHz (in
1-6 q-SPLit
Quick Split Offset Tuning - Select a tuning offset of up to ±100 kHz (in
2-0 Scn-PAuS
Scan Pause - Enables/disables pausing on activity while scanning.
2-1 Scn rES
Scan Resume Mode - Selects one of three scan- stop modes:
Carrier Stop - Scanning pauses on activity, resumes when signal disappears.
Carrier Timed Stop - Scanning pauses on activity for 5 seconds then resumes scanning for the next station (whether signal remains or not).
Carrier Timed Slow - Scanning slows down for 5 seconds after detecting activity, then resumes to normal scan rate.
2-2 (Not Used)
2-3 nScn-SPd
Memory Scan Speed - This sets the scan dwell time, which is the time duration that the scanner samples each memory channel. This duration can be set from 100 ~ 1000 msec, in 10 msec steps.
2-4 dScn-SPd
Dial (VFO) Scan Speed - This sets the dwell time that the scanner samples each VFO channel. This duration can be set from 1 ~ 100 msec, in 1 msec steps.
| page 99 |