CAT System Computer Control

Opcode Command Chart (3)

 

Command

Parameter Bytes

Opcode

 

Parameter Description

 

 

 

 

 

 

 

 

 

 

or Key

1st

2rd

3rd

4th

5th

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TUNER

T

81H

Switch Antenna Tuner ON (T = 01H) or OFF (T = 00H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tuner Start

82H

Start Antenna Tuning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual Operation

D

83H

Switch Dual Receive ON (D = 01H) or OFF (D = 00H)

 

 

 

 

 

 

 

 

 

 

 

[RPT]

R

84H

Switch Simplex Operation (R = 00H), Minus Shift (R = 01H),

 

 

or Plus Shift (R = 02H) for Repeater Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[AuB]

85H

Copy Data Display in VFO-A or VFO-B.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set SUB

 

 

 

 

 

Enter new operating frequency in F1 ~ F4, in BCD format:

 

 

VFO-B

F1

F2

F3

F4

8AH

 

 

see text for example.

 

 

 

 

 

 

Operating Freq.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select filter bandwidth for selected IF (see below):

 

 

BANDWIDTH

 

 

 

 

 

8.2 MHz

 

455 kHz

 

VFO

 

 

 

 

 

 

 

THRU: X4 = 09

6.0 kHz: X4 = 84

Both: X1 = 00

 

 

 

 

 

 

 

 

 

 

2ud & 3rd IF

X1

X4

8CH

2.4 kHz: X4 = 00 2.4 kHz: X4 = 80

VFO-A: X1 = 01

 

 

Filter Selection

 

 

 

 

 

2.0 kHz: X4 = 01

2.0 kHz: X4 = 81

VFO-B: X1 = 02

 

 

 

 

 

 

 

 

500 Hz: X4 = 02

500 Hz: X4 = 82

 

 

 

 

 

 

 

 

 

 

500 Hz: X4 = 03

500 Hz: X4 = 83

 

 

 

 

 

 

 

 

 

 

 

 

 

MEM. Channel

S

X

8DH

Tag memory channels 1 thruogh 99 (X = 01H ~ 6CH), to be

 

 

Scan Skip

skipped (S = 01H) or included (S = 00H) while scanning.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step VFO-A

T

8EH

Step frequency of VFO-A UP (T = 00H) or DOWN (T = 01H)

 

 

UP/DOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select one of 33 CTCSS subaudible tones

 

 

 

 

 

 

 

 

where E = 00H ~ 20H

 

 

 

 

 

 

 

 

 

 

 

 

E = 00H

67.0 Hz

 

E = 0BH 118.8 Hz

E = 16H 173.8 Hz

 

 

 

 

 

 

 

 

E = 01H

71.9 Hz

 

E = 0CH 123.0 Hz

E = 17H 179.9 Hz

 

 

 

 

 

 

 

 

E = 02H

77.0 Hz

 

E = 0DH 127.3 Hz

E = 18H 186.2 Hz

 

 

CTCSS

 

 

 

 

 

E = 03H

82.5 Hz

 

E = 0EH 131.8 Hz

E = 19H 192.8 Hz

 

 

Encoder

E

E

E

E

90H

E = 04H

88.5 Hz

 

E = 0FH 136.5 Hz

E = 1AH 203.5 Hz

 

 

Tone Frequency

 

 

 

 

 

E = 05H

94.8 Hz

 

E = 10H

141.3 Hz

E = 1BH 210.7 Hz

 

 

Select

 

 

 

 

 

E = 06H 100.0 Hz

 

E = 11H

146.2 Hz

E = 1CH 218.1 Hz

 

 

 

 

 

 

 

 

E = 07H 103.5 Hz

 

E = 12H 151.4 Hz

E = 1DH 225.7 Hz

 

 

 

 

 

 

 

 

E = 08H 107.2 Hz

 

E = 13H 156.7 Hz

E = 1EH 233.6 Hz

 

 

 

 

 

 

 

 

E = 09H 110.9 Hz

E = 14H 162.2 Hz

E = 1FH 241.8 Hz

 

 

 

 

 

 

 

 

E = 0AH 114.8 Hz

E = 15H 167.9 Hz

E = 20H 250.3 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruct radio to return digitized indications of various meter

 

 

 

 

 

 

 

 

level readings and front panel control settings (4 repeated

 

 

 

 

 

 

 

 

bytes, and F7H) selected by:

 

 

 

 

 

 

 

 

 

 

 

M = 00H Main S-Meter

M = 87H TUN Meter

 

 

Read Meter &

 

 

 

 

 

M = 01H Sub S-Meter

M = F0H Shuttle Jog Dial

 

 

F7H

M = 80H PO Meter

 

M = F1H CW Pitch Setting

 

 

Panel Controls

 

 

 

 

 

 

 

 

M = 81H ALC Meter

M = F2H Remote Control A/D Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M = 83H IC Meter

 

M = F3H SHIFT Setting

 

 

 

 

 

 

 

 

M = 84H VCC Meter

M = F4H WIDTH Setting

 

 

 

 

 

 

 

 

M = 85H SWR Meter

M = F5H EDSP Contour Selection

 

 

 

 

 

 

 

 

M = 86H MIC Meter

M = F6H EDSP NR Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set offset for RPT shift, valid values are

 

 

 

Repeater

X1

X2

X3

X4

F9H

0 ~ 500 kHz in 1-kHz step. Use BCD format for X2 ~ X4.

 

 

Offset

X1 is 10’s & 100’s of Hz

 

X2 is 1’s & 10’s of kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X3 is must be 00H, 01H, or 02H X4 is must be 00H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 