Vertex Standard FT-1000MP Command Parameter Bytes Opcode Or Key 1st 2rd 3rd 4th 5th, 70H, Edsp

Models: FT-1000MP

1 119
Download 119 pages 809 b
Page 97
Image 97

CAT System Computer Control

Opcode Command Chart (2)

Command

Parameter Bytes

Opcode

 

 

or Key

1st 2rd 3rd 4th

5th

 

Electronic

K1

K2

K3

K4

70H

Keyer

 

 

 

 

 

EDSP

 

 

 

 

Enhanced

 

 

 

 

Digital

P1 P2

75H

Signal

 

 

 

 

Plocessing

 

 

 

 

Parameter Description

Activates remote control and contest keyer functions. K1 = 00H (fixed value)

K2 = keyer function:

00H = Message 0

01H = Message 1

02H = Message 2

03H = Message 3

04H = CQ/ID Message

05H = Contest Number

06H = Decrement Contest Number

07H = Increment Contest Number

08H = Message Playback m/o Tx

09H = Write Message into Memory

K3 = 01H (fixed value)

K4 = 1BH (fixed value)

EDSP Settings, where P2 is:

RX EDSP OFF (30H), P1 = 00H

AM EDSP Demodulation On (31H), P1 = 00H

USB EDSP Demodulation (32H),

with audio response of 100 Hz ~ 3.1 kHz (P1 = 00H) or 300 Hz ~ 2.8 kHz (P1 = 10H)

LSB EDSP Demodulation (32H),

with audio response of 100 Hz ~ 3.1 kHz (P1 = 00H) or 300 Hz ~ 2.8 kHz (P1 = 10H)

AF Filter Off (40H), P1 = 00H

AF LPF On (41H),

where P1 = [FCUTOUT(Hz)]/20 (HEX format)

AF HPF On (42H),

where P1 = [FCUTOUT(Hz)]/20 (HEX format)

CW 240 Hz BWF (45H),

where P1 = FCENTER (BCD format)

CW 120 Hz BWF (46H),

where P1 = FCENTER (BCD format)

CW 60 Hz BWF (47H),

where P1 = FCENTER (BCD format)

Data Mode AF Filter On (48H), where P1 =

FSK (10H), SSTV (20H), Packet (30H), or FAX (40H) Random Noise Filter (4AH) Off/On (P1 = 00H/1YH) Audio Notch Filter (4BH) Off/On (P1 = 00H/10H)

AF Equalization (4EH), where P1 = Off (00H),

Bank 1 (10H), Bank 2 (20H), Bank 3 (30H), Bank 4 (40H) TX EDSP Off (B0H)

USB EDSP Modulation (B2H), with audio response of: 100 Hz ~ 3.1 kHz (P1 = 10H), 50 Hz ~ 3.1 kHz (P1 = 20H), 200 Hz ~ 3.1 kHz (P1 = 30H), 300 Hz ~ 3.1 kHz (P1 = 40H)

LSB EDSP Modulation (B3H), with audio response of: 100 Hz ~ 3.1 kHz (P1 = 10H), 150 Hz ~ 3.1 kHz (P1 = 20H), 200 Hz ~ 3.1 kHz (P1 = 30H), 300 Hz ~ 3.1 kHz (P1 = 40H),

AF Equalization (4EH), where P1 = Off (00H),

Bank 1 (10H), Bank 2 (20H), Bank 3 (30H), Bank 4 (40H)