Whirlpool TGS325E W, SF395LEE Q/Z/B Electronic Ignition System, Personal Injury/Fire Hazard

Models: FGS335E W/N FGS335E Q SF375PEE W/N SF350BEE W SF375PEE Q/Z SF385PEE W/N SF372BEE W/N SF360BEE W/N SF372BEE Q/Z SF385PEE Q/Z TGS325E W SF395LEE Q/Z/B

1 112
Download 112 pages 12.45 Kb
Page 13
Image 13

WARNING

Personal Injury/Fire Hazard

Do not, under any circumstances, cut or re- move the grounding prong from the range cord. Failure to provide proper polarization may cause shock and fire hazard.

ELECTRONIC IGNITION SYSTEM

When connecting an appliance that has an elec- tronic ignition system to a 120-volt AC receptacle, it is very important that the receptacle wiring is cor- rectly polarized and properly grounded. If the plug is not polarized properly, the ignitor module will not operate correctly.

1.The 120-volt AC receptacle should use 3- wires, and be polarized with two plug slots and a round grounding pin. Proper wiring for this type of receptacle is as follows:

a)The white wire is connected to the neutral side of the plug.

b)The black wire is connected to the hot (120-volt ac) side of the plug.

c)The green, or bare wire is connected to the round grounding pin of the plug.

3 - W I R E

AC RECEPTACLE

WHITE

BLACK

 

GREEN

Cooking Products Service Manual

Original July, 1996

4321891

© 1996 Whirlpool Corporation

Page 1-5

Once you are sure that the plug is polarized prop- erly, perform the next step.

2.Connect the power cord plug on the gas range to a 120-volt AC receptacle that is on a sepa- rately fused line.

 

3-PRONG

 

GROUNDING-

3-PRONG

TYPE WALL

GROUNDING PLUG

RECEPTACLE

POWER SUPPLY

 

CORD

GROUNDING PRONG

 

1-5