Whirlpool SF385PEE Q/Z, SF395LEE Q/Z/B, TGS325E W GAS Supply Requirements, If you smell gas

Models: FGS335E W/N FGS335E Q SF375PEE W/N SF350BEE W SF375PEE Q/Z SF385PEE W/N SF372BEE W/N SF360BEE W/N SF372BEE Q/Z SF385PEE Q/Z TGS325E W SF395LEE Q/Z/B

1 112
Download 112 pages 12.45 Kb
Page 14
Image 14

GAS SUPPLY REQUIREMENTS

WARNING

Fire Hazard

The gas appliance must be connected to a regulated gas supply.

Do not use an open flame to test for gas leaks from gas connections.

New A.G.A.-designed and certified flexible gas line should be used, when codes permit.

Do not store or use gasoline, or any other flammable vapors and liquids, in the vicinity of this, or any other appliance.

If you smell gas:

Do not light any appliance.

Do not operate any electrical switches.

Do not use the telephone.

Call the gas supplier immediately from a neighbor’s telephone, and follow the gas supplier’s instructions carefully.

If you cannot reach the gas supplier, call the fire department.

Failure to follow these instructions could result in fire, explosion, or other personal injury.

This range is factory set for use with natural gas. It is designed-certified by the American Gas Asso- ciation (A.G.A.) for natural or L.P. gases with the appropriate conversion. The model/serial rating plate has information on the type of gas that can be used. If the type of gas listed does not agree with the type of gas available, check with the local gas supplier. Conversion must be done by a qualified service technician.

Arigid, 3/4" gas supply pipe, must be provided for both natural and L.P. gas at the gas range installa- tion location. Long lengths of smaller size pipe may result in an insufficient supply of gas to the range. Pipe-joint compounds, made for use with natural and L.P. gas, must be used.

If local codes and ordinances permit, new A.G.A.- approved, flexible metal tubing can be used for connecting the appliance to the gas supply line. Do not kink or damage the flexible tubing when moving the appliance. A 3/4" male pipe thread is needed for connecting to the female pipe threads of the pres- sure-regulator.

GENERAL

This installation must conform with local codes and ordinances. In the absence of local codes, installa- tion must conform with the American National Standard, National Fuel Gas Code ANSI Z223.1— latest edition.*

Copies of the standards listed above may be ob- tained from:

*American Gas Association 1515 Wilson Boulevard Arlington, Virginia 22209

Input ratings shown on the model/serial rating plate (located on the frame behind the storage door panel) are for elevations up to 2,000 feet. For elevations above 2,000 feet, contact the local ser- vice company.

The supply line must be equipped with an ap- proved shutoff valve. This valve should be located in the same room as the appliance, and should be in a location that allows easy access to turn the gas supply on and off. Do not block the access to the shutoff valve. Never reuse an old connector when installing a new range.

1-6

Page 14
Image 14
Whirlpool SF385PEE Q/Z, SF395LEE Q/Z/B, TGS325E W, SF372BEE Q/Z, SF360BEE W/N GAS Supply Requirements, If you smell gas