DUAL GAS SAFETY VALVE
Description
The purpose of the gas safety valve is to control gas to the bake and broil burners.
The dual gas safety valve has one gas input and two gas outlets, one for the bake burner, and one for the broil burner. It uses two iden- tical
Test Procedure
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser- vicing unit.
Failure to do so could result in death or electrical shock.
1.Broil burner operates, but the bake burner will not come on.
a)Place the oven in the BAKE mode, set the oven thermostat to 350 degrees, and observe the bake igniter. If the igniter glows, go to step c. If the igniter does not glow, go to step b.
b)Disconnect power, remove the wires from the bake side of the gas safety valve, and connect an ohmmeter across the terminals of the gas safety
valve. If the meter reads approximately 1 Ω, the problem is in another compo- nent of the bake circuit. If the meter reads infinity, replace the gas safety valve.
c)Connect an ampmeter to the bake cir- cuit. If the meter reads less than 3.2 amps, replace the bake igniter. If the meter reads over 3.2 amps, replace the gas safety valve.