REMOVING THE OVEN DOOR LATCH & ACTUATOR ROD
Sealed Burner Models
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before servic- ing unit.
Failure to do so could result in death or electri- cal shock.
CAUTION: When you work on the gas range, be careful when handling the sheet metal parts. Sharp edges may be present, and you can cut yourself if you are not careful.
1.Pull the range away from the wall so that you can access the back.
2.Turn off the gas to the range and disconnect the power cord from the wall outlet.
3.Remove the maintop (use the procedure start- ing on page
4.Lift the left and right venturi from the burner box.
7.Remove the screws from the three gas mani- fold brackets.
GAS MANIFOLD
BRACKETS
8.Remove the two screws holding the burner box to the back of the range (see the large inset on the next page).
9.Remove the eight top screws from the oven burner box.
LEFT VENTURI | BURNER |
| BOX |
RIGHT VENTURI
5.Pull the knobs off the gas valves.
6.Open the oven door, remove the three screws from the bottom of the manifold panel, and remove the panel.
MANIFOLD PANEL
KNOB
10.Lift the front of the burner box and spread the left and right insulation retainers, (see the illustration on the next page), then pull the burner box forward, and remove it.
11.Remove the screws and rubber spacer from the oven door latch, (see the small inset on the next page), and unhook the end of the actua- tor rod from the oven door latch arm.
12.To remove the actuator rod, raise it straight up, and unhook it from the solenoid and switch assembly bracket.
SCREWS