User Safety
Humidity should be 70 percent or below at 90° F, and temperature should be 82° F or below at 85 percent humidity.
Note: Sudden temperature fluctuations can affect print quality. Rapid heating of a cold room can cause condensation inside the machine, directly interfering with image transfer.
Printer Clearance
Place the printer in an area where there is adequate space for ventilation, operation, and servicing. The recommended minimal spacing is:
Overhead Clearance:
•35 cm (13.8 in.) above the printer
Total Height Requirements:
•Printer: 47 cm (18.5 in.)
•Add 14 cm (5.5 in.) for the
Other Clearances:
•13 cm (5 in.) behind the printer
•60 cm (23.6 in.) in front of the printer
•10 cm (3.9 in.) on the left side of the printer
•10 cm (3.9 in.) on the right side of the printer
Operational Guidelines
•Do not block or cover the slots and openings on the printer. The printer may overheat without adequate ventilation.
•For optimum performance, use the printer at elevations below 3,500 m (11,480 ft.).
•Do not place the printer near a heat source.
•Do not place the printer in direct sunlight to avoid exposing
•Do not place the printer in line with the cold air flow from an air conditioning system.
Phaser® 6280 Printer
10