2
The Pattern Mode
14. Pattern & Phrase Editing — The Pattern Jobs
RS7000 143
5Data
[Settings] 000 ~ 127
(-8192 ~ +8191 for pitch bend data)
Specifies the lower and upper limits for the data range to be
created. The left value is the lower limit, and the right value
is the upper limit.
6Clock
[Settings] 001 ~ 999
Specifies the number of clocks to be inserted between each
created event.
7Curve
[Settings] -16 ~ +16
Specifies the “curve” of the continuous data.
Refer to the graph below for approximate curve shapes.
Thins out the specified type of continuous data in the specified
range to save memory space.
1Phrase
[Settings] 001 ~ 256
2Range
[Settings] Measure:Beat:Clock
001:1:000 ~ 257:1:000
Sets the range of measures/beats/clocks over which the job
will be applied.
3Event Type
[Settings] PB (Pitch bend)
CC (Control change):000 ~ 127, ALL
CAT (Channel aftertouch)
PAT (Polyphonic aftertouch)
Selects the event type to be thinned.
Changes the values of a specified type of control change data
— pitch bend, control change, aftertouch, etc. — in the spec-
ified range.
The data value is calculated as follows.
Value = original data × Rate + Offset.
If the resultant value exceeds the allowable range it will be
set to the maximum or minimum value.
1Phrase
[Settings] 001 ~ 256
2Range
[Settings] Measure:Beat:Clock
001:1:000 ~ 257:1:000
Sets the range of measures/beats/clocks over which the job
will be applied.
3Event Type
[Settings] PB (Pitch bend)
CC (Control change):000 ~ 127, ALL
CAT (Channel aftertouch)
PAT (Polyphonic aftertouch)
Selects the event type to be modified.
15 Thin OutNOTE
The Thin Out job will not work on continuous
data that has a clock interval of greater than 60
clocks per event.
Start point
This distance
specified by Clock
End point
Curve = +16 Curve = 0 (linear) Curve = -16
1 2
3[Knob 2] [Knob 3] [F4]
16 Modify Control Data
1 2
3
6