3 - 56
INSP
ADJ
FUSE INSPECTION2. Check:
•Continuity
2 Reserve fuse
Checking steps:
•Remove the fuse 1.
•Connect the pocket tester to the fuse and
check the continuity.
N
OTE:
Set the pocket tester selector to “Ω × 1”.
Pocket tester:
YU-3112-C/90890-03112
•If the pocket tester indicates “∞”, replace
the fuse.
21
3. Replace:
•Blown fuse
WARNING
Never use a fuse with an amperage rating
other than that specified. Improvising or
using a fuse with the wrong amperage rat-
ing may cause extensive damage to the
electrical system, cause the starting and
ignition systems to malfunction and could
possibly cause a fire.
4. Install:
•Fuse cover
•Seat
Replacement steps:
•Set the main switch to “OFF”.
•Install a new fuse of the correct amperage.
•Set on the switches to verify if the electri-
cal circuit is operational.
•If the fuse immediately blows again, check
the electrical circuit.
Items Amperage rating Q’ty
Main fuse 10 A 1